Topcable Low voltage cables Medium voltage cables Topmatic

LME Cotizaciones

Top Cable

TOPFLAT XTREM
LOW VOLTAGE
300/500 V
DIN VDE 0250-809
Reference Norm


TOPFLAT XTREM  

Extreme flexibility when moving

Conductor: Electrolytic copper, class 5 in accordance with IEC 60228.


Insulation: Thermosetting rubber insulation (EPR), type GI1 according to DIN VDE 0207 -20.

The standard identification is as follows:
-4 conductors brown + black + grey + yellow/green
-5 conductors brown + black + grey + blue + yellow/green
-6 or more conductors black numbered + yellow/green


Outer sheath: Heavy-duty rubber outer sheath, black colour, type 5GM2 according to DIN VDE 0207 - 21.


Applications: The Topflat Xtrem cable is particularly suitable for connecting crane bridges, hoists, elevators, lifts, etc.


Print

CHARACTERISTICS

Flexible conductor, class 5 Minimum service temperature: -25ºC Maximum service temperature: 90ºC
 
Maximum service temperature: 60ºC Maximum short-circuit temperature: 250ºC (max 5 s) Minimum bending radius: 10 x cable diameter
 
Meter by meter marking Impact resistance: AG2. Medium impact Outdoor installation: permanent
 
Water resistance: AD7 immersion Chemical & oil resistance: excellent

INSTALLATION CONDITIONS

Industrial use Crane bridges
 
Elevators Robotics
 