TOXFREE ZH FR-N1 X1G1

Halogen free (LSZH) power cable for public places.


TOXFREE ZH FR-N1 X1G1 is a LSZH safety cable. In the event of fire, it does not emit toxic gases, nor does it give off corrosive gases, avoiding any possible damage to people or electronic equipment. For these reasons, it is highly recommended for use in public places such as: hospitals, schools, museums, airports, bus terminals, shopping malls, offices, laboratories, etc.

TOXFREE ZH FR-N1 X1G1 cable performance

Electrical performance

LOW VOLTAGE 0,6/1 kV

Standard

UNE-EN 60332-1 / HD 604

Approvals

CE

LCIE (in progress)

Construction Product Regulation

B2ca -s1a, d1, a1

Thermal performance

Maximum service temperature: 90ºC.

Maximum short-circuit temperature: 250ºC (max. 5 s).

Minimum service temperature: -40ºC (fixed and protected installations).

Fire performance

Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

Fire non-propagation based on UNE-EN 60332-3, IEC 60332-3 and EN 50399.

LSZH (Low Smoke Zero Halogen) based on  UNE-EN 60754-1 and IEC 60754-1.

Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60%.

Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

Reaction to fire CPR B2ca -s1a, d1, a1 according to 50575. 

Mechanical performance

Minimum bending radius: x8 cable diameter.

Impact resistance: AG2 Medium severity.

Chemical performance

Chemical & Oil resistance: Acceptable.

Water performance

Water resistance: AD5 Jets.

Other

Meter by meter marking.

Installation conditions

Open air. Buried.

In conduit.

Applications

Industrial use.

Public places.

TOXFREE ZH FR-N1 X1G1 cable design

Conductor

Electrolytic copper, class 1 (FR-N1 X1G1-U) or class 2 (FR-N1 X1G1-R), based on EN 60228 and IEC 60228.

Insulation

Cross-linked flame non propagation polyethylene (XLPE).

The standard identification of insulated conductors is the following:

1x                                        Natural

2x                                       Blue + Brown

3G                                      Blue + Brown + Green/yellow

3x                                       Brown + Black + Grey

3x + 1x                              Brown + Black + Grey + Blue (reduced cross section)

4G                                        Brown + Black + Grey + Green/yellow

4x                                       Brown + Black + Grey + Blue

5G                                      Brown + Black + Grey + Blue + Green/yellow

6G or more conductors: Black numbered + Green/yellow

Outer sheath Low Smoke Zero Halogen (LSZH) polyolefin. Green colour (*), non-toxic and fire retardant. (*) Other outer sheath colours available on request

  • LOW VOLTAGE 0,6/1kV

  • Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

  • Minimum bending radius: x8 cable diameter

  • B2ca -s1a, d1, a1

Cable Specifications


CHEMICAL PERFORMANCE

  • Chemical & Oil resistance: Acceptable.

ELECTRICAL PERFORMANCE

  • LOW VOLTAGE 0,6/1kV

FIRE PERFORMANCE

  • Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.

  • Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

  • Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

  • Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%

  • LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1.

MECHANICAL PERFORMANCE

  • Impact resistance: AG2 Medium severity.

THERMAL PERFORMANCE

  • Maximum service temperature: 90ºC.

  • Maximum short-circuit
    temperature: 250ºC (max. 5 s).

  • Minimum service temperature: -40ºC (fixed and protected installations)

WATER PERFORMANCE

  • Water resistance: AD5 Jets.

Other properties


APPLICATIONS

  • Industrial use.

  • Public places.

APPROVALS

  • CE

CONSTRUCTION PRODUCT REGULATION

  • B2ca s1a, d1, a1

BASED ON

  • EN 60228 / IEC 60228

INSTALLATION CONDITIONS

  • Buried.

  • In conduit.

  • Open Air.

OTHERS

  • Meter by meter marking.

Technology


  • 1. Conductor
    • Electrolytic copper, class 1 (FR-N1 X1G1-U) or class 2 (FR-N1 X1G1-R), based on EN 60228 and IEC 60228.
  • 2. Insulation
    • Cross-linked polyethylene (XLPE)
    • The standard identification of insulated conductors is the following:
    • 1 x Natural
    • 2 x Blue + Brown
    • 3 G Blue + Brown + Yellow/green
    • 3 x Brown + Black + Grey
    • 3 x + 1 x Brown + Black + Grey + Blue (reduced cross section)
    • 4 G Brown + Black + Grey + Yellow/green
    • 4 x Brown + Black + Grey + Blue
    • 5 G Brown + Black + Grey + Blue + Yellow/green
    • 6 G or more conductors: Black numbered + Yellow/green.
  • 3. Outer sheath
    • Low Smoke Zero Halogen (LSZH) polyolefin. Green colour, non-toxic and fire retardant.

Other cables with similar properties


TECHNICAL & SALES SUPPORT

If you have any questions, please contact us. We’ll do our best to help.



Your message has been sent. Thank you

To download the cable datasheet, please complete the form below


Your message has been sent. Thank you