TOXFREE ZH ROZ1-K (AS) VFD EMC 1,8/3 kV

3kV flexible EMC LSZH screened cable for Variable Frequency Drive cables (VFD cables).


TOXFREE ZH ROZ1-K AS VFD EMC 1,8/3kV cable has been specially designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI).


  • LOW VOLTAGE 0.6/1 (1,2) KV

  • Flame non-propagation based on UNE-EN 60332-1 and IEC 603...

  • Maximum service temperature: 90ºC.

  • UNE-EN 60332-1 / UNE-EN 60332-3-22 / UNE-EN 50267-1 / UNE...

  • Industrial use / Variable Frequency Drive (VFD)

Cable Specifications


CHEMICAL PERFORMANCE

  • Chemical & Oil resistance: Good.

ELECTRICAL PERFORMANCE

  • LOW VOLTAGE 0.6/1 (1,2) KV

FIRE PERFORMANCE

  • Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.

  • Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

  • Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

  • Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%

  • LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1.

MECHANICAL PERFORMANCE

  • Impact resistance: AG2 Medium severity.

  • Minimum bending radius: x10 cable diameter.

THERMAL PERFORMANCE

  • Maximum service temperature: 90ºC.

  • Maximum short-circuit
    temperature: 250ºC (max. 5 s).

  • Minimum service temperature: -40ºC (fixed and protected installations)

WATER PERFORMANCE

  • Water resistance: AD5 Jets.

Other properties


APPROVALS

  • ABS (in progres)
  • CE

  • DNV-GL

  • RoHS

APPLICATIONS

  • Industrial use.

  • Variable Frequency Drive (VFD)

BASED ON

  • IEC 60502-1 / IEC 60092-353

INSTALLATION CONDITIONS

  • Buried.

  • In conduit.

  • Open Air.

OTHERS

  • Electric fields resistant.

  • Meter by meter marking.

International norm

  • IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034

National norm / European:

  • UNE-EN 60332-1 / UNE-EN 60332-3-22 / UNE-EN 50267-1 / UNE-EN 61034

Technology


  • 1. Conductor
    • Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
  • 2. Grounding Conductor
    • The grounding conductor is divided into three conductors; the equivalent cross section is approximately 50% of the section of the phase conductor.
  • 3. Insulation
    • Cross-linked polyethylene (XLPE)
    • The standard identification of insulated conductors is the following:
    • 4G grey + brown + black + yellow/green (up to 4 mm2)
    • 3x + 3G grey + brown + black + yellow/green (3 x) (from 6 mm2 onwards)
  • 4. Screen
    • Aluminium-polyester tape screen, helically placed over the insulated conductors. Over the tape there is a tinned copper braid screen. The tape and the braid act as a double screen to cut out all of the the electromagnetic interference.The screen has a cover of 100% and its total section is approximately 10% of one of the conductors.
  • 5. Outer sheath
    • Polyolefin LSZH outer sheath, black colour.

Other cables with similar properties