Cable > POWERHARD® F RVFV-K

POWERHARD® F
RVFV-K

Armoured cable with double steel or aluminium tape armour.
ACCORDING TO: IEC 60502-1., UNE 21123-2.

POWERHARD® F RVFV-K cable is highly recommended for use in installations where the presence of rodents could imply a threat to the cable.

Aluminium Steel Tape (AST) or Double Steel Tape (DST) armor.
Enhanced Mechanical Protection
Versatility and durability for fixed armoured installations

Typical applications of
POWERHARD® F RVFV-K

Select...
Industrial facilities Construction sites Power distribution
POWERHARD® RVFV-K AST/DST cables provide long-term durability for industrial use, making them ideal for demanding industrial facilities where the presence of rodents could imply a threat to the cable
POWERHARD® RVFV-K AST/DST power cables are perfect for construction sites, ensuring reliable power distribution in outdoor and temporary installations.
POWERHARD® RVFV-K AST/DST power cables provide superior flexibility and durability, and are ideal for efficient and safe power distribution and electricity transmission in utility and industrial grids.
Industrial facilities
POWERHARD® RVFV-K AST/DST cables provide long-term durability for industrial use, making them ideal for demanding industrial facilities where the presence of rodents could imply a threat to the cable
Construction sites
POWERHARD® RVFV-K AST/DST power cables are perfect for construction sites, ensuring reliable power distribution in outdoor and temporary installations.
Power distribution
POWERHARD® RVFV-K AST/DST power cables provide superior flexibility and durability, and are ideal for efficient and safe power distribution and electricity transmission in utility and industrial grids.

Resources for engineers

POWERHARD® F RVFV-K Technical datasheet Download file
POWERHARD® F RVFV-K DoP Download file
POWERHARD® F RVFV-K

Technical specifications

Application

POWERHARD® RVFV-K cable is especially suitable for fixed installations that may be subject to mechanical aggression. It is highly recommended for use in installations where the presence of rodents could imply a threat to the cable (such as warehouses, production plants and agricultural facilities). At the same time, its use is recommended for street lighting installations.

Construction

Insulation

XLPE.
The standard identification of insulated conductors according to HD
308 is the following:
1 x Natural.
2 x Blue + Brown.
3 G Blue + Brown + Green/Yellow.
3 x Brown+ Black+ Grey.
3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section).
4 G Brown + Black + Grey + Green/Yellow.
4 x Brown + Black + Grey + Blue.
5 G Brown + Black + Grey + Blue + Green/yellow.
6 or more: Black numbered + Green/Yellow.

Armour

Double steel or aluminium tape armour. Aluminium armour is used in single-core cables to avoid parasite currents that may overheat the cable. Steel tape is used in the multicore cables.

Separation sheath / beding

PVC type DMV-18 according to UNE-HD 603 and type ST2 according
to IEC 60502-1.

Outer sheath

PVC (flexible).
Black colour.

Standards / Compliance

ACCORDING TO: IEC 60502-1., UNE 21123-2.

Standards and approvals

  • CE.
  • BUREAU VERITAS.
  • RoHS.

Construction Products Regulation

  • Eca.

 

Disclaimer
The information displayed on this website is provided for reference purposes only and is not legally binding. Specifications, values, and technical data may be subject to change without notice. To obtain verified and up-to-date technical data for a specific cable, please download Top Cable’s official Technical Specification in PDF format. The PDF document constitutes the sole authoritative source of product data.

 

Characteristics

Electrical performance 0,6/1kV
Thermal performance Maximum conductor temperature: 90ºC. Maximum short-circuittemperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed and protected installations). Minimum installation and handling temperature: 0ºC.
Fire performance Flame non-propagation according to EN 60332-1 and IEC 60332-1. Reaction to fire CPR: Eca according to EN 50575. Reduced halogens emission. Chlorine <15%.
Mechanical performance Minimum bending radius during instrallation: x10 cable diameter. Impact resistance: AG4 High severity. Rodent proof
Environmental performance Chemical & Oil resistance: Good. UV Resistant: UNE 211605. Water resistance: AD7 Immersion.
Installation conditions Open Air. Buried. In conduit.
Other Meter by meter marking.

Why choose our POWERHARD® F RVFV-K

  • cable icon

    As cable manufacturers, we ensure cost-effective premium quality and lasting performance.

  • laboratory icon

    Our in-house labs guarantee rigorous cable quality, reliability, and standards compliance.

  • global icon

    Global cable delivery solutions—expert logistics for seamless supply.

  • logistic icon

    Full cable stock, ready for fast delivery- shortest lead times.
    Largest European stockholding.

  • EPD icon

    EPD-certified cables: Sustainable manufacturing for your Scope 3 success.

  • client support icon

    Expert, friendly and professional sales team offering a fast & efficient customer service. Global customers are welcome!

Need expert advice, a custom solution, or an RFQ?

Questions? We’ll help you find a solution.