Cable > TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

TOPDRIVE® VFD (EMC)
ROZ1-K 0,6/1kV

Flexible LSZH screened cable for Variable Frequency Drive (VFD) cables .
ACCORDING TO: IEC 60502-1., IEC 60092-353.

TOPDRIVE® VFD ROZ1-K cable has been specially designed for VFD Motors and where it is necessary to limit the effects of electromagnetic interference.

Screen 100% shielding coverage
For VFD applications
EMI protection

Typical applications of
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

Select...
Variable Frequency Drive Motors Industrial facilities Fixed installations
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable is specifically engineered to suppress capacitive leakage currents and dampen reflected wave phenomena, ensuring reliable motor operation and protecting against damaging voltage spikes. A 3+3 configuration in a VFD cable utilizes three main power conductors alongside three symmetrically arranged grounding conductors, which provides a balanced impedance path for common-mode currents to effectively cancel out electromagnetic interference.
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cables excel in industrial facilities by minimizing electromagnetic noise emissions through superior symmetrical shielding and their flame-retardant, halogen-free design significantly reduces smoke and toxic gas release during a fire, enhancing both operational integrity and personnel safety.
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable ensure long-term stability against thermal aging and mechanical stress, guaranteeing sustained performance and reliability over the lifespan of a fixed installation.
Variable Frequency Drive Motors
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable is specifically engineered to suppress capacitive leakage currents and dampen reflected wave phenomena, ensuring reliable motor operation and protecting against damaging voltage spikes. A 3+3 configuration in a VFD cable utilizes three main power conductors alongside three symmetrically arranged grounding conductors, which provides a balanced impedance path for common-mode currents to effectively cancel out electromagnetic interference.
Industrial facilities
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cables excel in industrial facilities by minimizing electromagnetic noise emissions through superior symmetrical shielding and their flame-retardant, halogen-free design significantly reduces smoke and toxic gas release during a fire, enhancing both operational integrity and personnel safety.
Fixed installations
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable ensure long-term stability against thermal aging and mechanical stress, guaranteeing sustained performance and reliability over the lifespan of a fixed installation.

Resources for engineers

TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV Technical datasheet Download file
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV DoP Download file
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

Technical specifications

Application

TOPDRIVE® VFD ROZ1-K cable has been designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI). This is a flexible cable for fixed insatllations, for variable speed motors or pumps.

Construction

Protective conductor

The ground conductor is divided into three conductors; the equivalent cross-section is approximately 50% of the section of the phase conductor.
For 4G cables, ground conductor has the same cross-section as the phase conductors.

Insulation

XLPE.
The standard identification of insulated conductors is the following:
3x + 3G Grey + Brown + Black + Green/yellow (3 G) (from 6 mm2 onwards).
4 G Grey + Brown + Black + Green/yellow (up to 4 mm2).

Assembly of cores

For 3 x + 3 G cables, the three phase conductors are cabled helically with the three protective conductors distributed in the interstices.
For 4 G cables, the three phase conductors and protection conductor are cabled helically.

Screen

Overlapping aluminium-polyester tape screen with 100% coverage + tinned copper drain wire.

Outer sheath

Polyolefin LSZH.

Standards / Compliance

ACCORDING TO: IEC 60502-1., IEC 60092-353.

Standards and approvals

  • BUREAU VERITAS.
  • ABS.
  • DNV-GL.
  • LLOYD’S REGISTER
  • RoHS
  • CE

Construction Products Regulation

  • Cca-s1a, d1, a1.

 

Disclaimer
The information displayed on this website is provided for reference purposes only and is not legally binding. Specifications, values, and technical data may be subject to change without notice. To obtain verified and up-to-date technical data for a specific cable, please download Top Cable’s official Technical Specification in PDF format. The PDF document constitutes the sole authoritative source of product data.

 

Characteristics

Electrical performance 0,6/1kV
Thermal performance Maximum conductor temperature: 90ºC. Maximum short-circuittemperature: 250ºC (max. 5 s). Maximum ambient temperature: 60 ºC. Minimum installation and handling temperature: 0 °C. Minimum service temperature: -40ºC (fixed and protected installations).
Fire performance Flame non-propagation according to EN 60332-1 / IEC 60332-1. Fire non-propagation according to EN 60332-3 / IEC 60332-3 and EN 50399. Reaction to fire CPR: Cca-s1a, d1, a1 according to EN 50575. LSZH (Low Smoke Zero Halogen) according to IEC 60754-1. Low corrosive gases emission according to EN 60754-2 / IEC 60754-2. Low smoke emission according to EN 61034 / IEC 61034:Light transmittance > 80%.
Mechanical performance Minimum bending radius: x10 cable diameter. Impact resistance: AG2 Medium severity.
Environmental performance Chemical & Oil resistance: Acceptable. UV resistant according to EN 50618. Water resistance: AD5 Jets.
Installation conditions Being very performant cables there are, however, certain precautions that must be taken into account during installation: - Always respect the bending radius of the cable. Radius below the minimums indicated can cause damage or breakage in the outer sheath. - Precautions design of the laying. It is necessary that the laying of the cable is done in a careful way, taking care not to damage the outer sheath in irregular areas, sharp edges, etc. - Fixings/Fastenings. Adapt fastenings so that the cable adopts a natural position in the laying to avoid stress concentration in the outer sheath. Allow a certain degree of freedom of movement in order to absorb possible movements produced by temperature variations. Open Air Buried In conduit
Other Meter by meter marking.

Why choose our TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

  • cable icon

    As cable manufacturers, we ensure cost-effective premium quality and lasting performance.

  • laboratory icon

    Our in-house labs guarantee rigorous cable quality, reliability, and standards compliance.

  • global icon

    Global cable delivery solutions—expert logistics for seamless supply.

  • logistic icon

    Full cable stock, ready for fast delivery- shortest lead times.
    Largest European stockholding.

  • EPD icon

    EPD-certified cables: Sustainable manufacturing for your Scope 3 success.

  • client support icon

    Expert, friendly and professional sales team offering a fast & efficient customer service. Global customers are welcome!

Need expert advice, a custom solution, or an RFQ?

Questions? We’ll help you find a solution.