Cable > X-VOLT® RHZ1 (AS) AL / OL / 2OL

X-VOLT®
RHZ1 (AS) AL / OL / 2OL

Medium Voltage aluminium cable, XLPE insulation.
ACCORDING TO: IEC 60502-2., UNE-HD 620-10E (type 10E-5)

X-VOLT® RHZ1 (AS) is a halogen free, with low smoke emission and no fire propagation cable for fixed installations.

Medium Voltage cable
Aluminium cable
Enhanced Fire Safety LSZH / CPR

Typical applications of
X-VOLT® RHZ1 (AS) AL / OL / 2OL

Select...
Distribution networks Industrial facilities Street lighting
X-VOLT® medium voltage cables are the premier LSZH choice for distribution networks, offering reliable 10kV, 11kV, 20kV, 22kV, 30kV, 33kV and 69kV power transmission with aluminum conductors.
X-VOLT® medium voltage cables are the premier LSZH choice for industrial facilities. Available CPR-compliant version for enhanced fire safety.
X-VOLT® medium voltage cables are the premier LSZH choice for urban lighting grids, tunnels, and smart city infrastructure, meeting stringent international standards for durability and efficiency.
Distribution networks
X-VOLT® medium voltage cables are the premier LSZH choice for distribution networks, offering reliable 10kV, 11kV, 20kV, 22kV, 30kV, 33kV and 69kV power transmission with aluminum conductors.
Industrial facilities
X-VOLT® medium voltage cables are the premier LSZH choice for industrial facilities. Available CPR-compliant version for enhanced fire safety.
Street lighting
X-VOLT® medium voltage cables are the premier LSZH choice for urban lighting grids, tunnels, and smart city infrastructure, meeting stringent international standards for durability and efficiency.

Resources for engineers

X-VOLT® RHZ1 (AS) AL / OL / 2OL Technical datasheet Download file
X-VOLT® RHZ1 (AS) AL / OL / 2OL DoP Download file
X-VOLT® RHZ1 (AS) AL / OL / 2OL

Technical specifications

Application

X-VOLT® RHZ1 (AS) is a Medium Voltage aluminium cable halogen free, with low smoke emission and no fire propagation for fixed installations. Suitable for transport and distribution of electric power in medium voltage networks.

Construction

Conductor

Aluminium class 2. Optionally, with longitudinal water tightness (cable type -2OL).

Conductor screen

Screen over the conductor, made of thermosetting semiconductor material.

Insulation

XLPE.
Cross linked in catenary line with nitrogen atmosphere by a triple layer extrusion process.

Insulation screen

Screen over the insulation, made of thermosetting and strippable semiconductor material.

Metallic screen

Copper wires and copper tape screen, with a minimum cross-section of 16mm2.

Longitudinal water tightness

Hygroscopic tape completely covering the screen (cable type -OL and -2OL).

Filler

Additional fireproof polyolefin layer, halogen free.

Outer sheath

Polyolefin.
Red colour with two green stripes.
Other colours under request.

Standards / Compliance

ACCORDING TO: IEC 60502-2., UNE-HD 620-10E (type 10E-5)

Standards and approvals

  • AENOR

Construction Products Regulation

  • Cca-s1b,d2,a1

 

Disclaimer
The information displayed on this website is provided for reference purposes only and is not legally binding. Specifications, values, and technical data may be subject to change without notice. To obtain verified and up-to-date technical data for a specific cable, please download Top Cable’s official Technical Specification in PDF format. The PDF document constitutes the sole authoritative source of product data.

 

Characteristics

Electrical performance 6/10 (12) kV 12/20 (24) kV 18/30 (36) kV
Thermal performance Maximum service temperature: 90ºC. Maximum short-circuittemperature: 250ºC (max. 5 s). Minimum service temperature: -15ºC.
Fire performance Flame non-propagation according to EN 60332-1 and IEC 60332-1. Fire non-propagation according to EN 50399. Reaction to fire CPR: Cca-s1b, d2, a1 according to EN 50575. Halogen free according to EN 60754-1 / IEC 60754-1. Low corrosive gases emission according to UNE-EN 60754-2 and IEC 60754-2. Low smoke emission according to EN 61034 and IEC 61034. Light transmittance > 60%.
Mechanical performance Minimum bending radius: 15x cable diameter. Minimum bending radius during installation: 20x cablediameter. Abrasion resistant Tear resistant.
Environmental performance UV Resistant: UNE 211605. Water Resistance: AD6 Waves.
Installation conditions Open Air. Buried. In conduit.
Other Meter by meter marking.

Why choose our X-VOLT® RHZ1 (AS) AL / OL / 2OL

  • cable icon

    As cable manufacturers, we ensure cost-effective premium quality and lasting performance.

  • laboratory icon

    Our in-house labs guarantee rigorous cable quality, reliability, and standards compliance.

  • global icon

    lobal cable delivery solutions—expert logistics for seamless supply.

  • logistic icon

    Full cable stock, ready for fast delivery- shortest lead times.
    Largest European stockholding.

  • EPD icon

    EPD-certified cables: Sustainable manufacturing for your Scope 3 success.

  • client support icon

    Expert, friendly and professional sales team offering a fast & efficient customer service. Global customers are welcome!

Need expert advice, a custom solution, or an RFQ?

Questions? We’ll help you find a solution.