{"id":22843,"date":"2024-04-15T14:01:00","date_gmt":"2024-04-15T14:01:00","guid":{"rendered":"https:\/\/www.topcable.com\/blog-electric-cable\/?p=22843"},"modified":"2025-07-28T11:11:33","modified_gmt":"2025-07-28T11:11:33","slug":"normativas-para-cables-marinos","status":"publish","type":"post","link":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/normativas-para-cables-marinos\/","title":{"rendered":"Normativas para cables marinos a nivel internacional"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Los cables marinos se someten a rigurosos procesos de tests y certificaci\u00f3n para garantizar la <a title=\"instalaci\u00f3n cables marinos\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/instalacion-de-cables-marinos\/\" target=\"_blank\" rel=\"noreferrer noopener\">m\u00e1xima fiabilidad y seguridad de la instalaci\u00f3n<\/a>. A continuaci\u00f3n repasamos las principales normativas para cables marinos a nivel internacional. Estos cables deben cumplir las normativas internacionales para garantizar la seguridad a bordo. <a href=\"https:\/\/www.iec.ch\/homepage\" target=\"_blank\" rel=\"noreferrer noopener\">La International Electromechanical Commission (IEC)<\/a> destaca como la referencia mundial para la fabricaci\u00f3n y el uso de cables marinos.<\/strong><\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left-text counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<label for=\"ez-toc-cssicon-toggle-item-6a6dce0811b44\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"ez-toc-title\" style=\"cursor:inherit\">INDEX<\/span>\n<span class=\"ez-toc-cssicon\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #444444;color:#444444\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #444444;color:#444444\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-6a6dce0811b44\" checked \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/normativas-para-cables-marinos\/#algunas-de-las-normativas-para-cables-marinos-mas-comunes-iec\" >ALGUNAS DE LAS NORMATIVAS PARA CABLES MARINOS M\u00c1S COMUNES (IEC)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/normativas-para-cables-marinos\/#top-cable-un-proveedor-global-de-la-industria-naval\" >TOP CABLE, UN PROVEEDOR GLOBAL DE LA INDUSTRIA NAVAL<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/normativas-para-cables-marinos\/#top-cable-fabricante-y-proveedor-de-confianza-de-cables-marinos\" >TOP CABLE, FABRICANTE Y PROVEEDOR DE CONFIANZA DE CABLES MARINOS<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"algunas-de-las-normativas-para-cables-marinos-mas-comunes-iec\"><\/span>ALGUNAS DE LAS NORMATIVAS PARA CABLES MARINOS M\u00c1S COMUNES (IEC)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60092-350<\/strong><\/td><td>Instalaciones el\u00e9ctricas en barcos &#8211; Apartado 350: M\u00e9todos generales de construcci\u00f3n y ensayo de cables de energ\u00eda, control e instrumentaci\u00f3n para aplicaciones a bordo de barcos y en alta mar.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60092-352<\/strong><\/td><td>Instalaciones el\u00e9ctricas en barcos &#8211; Apartado 352: Selecci\u00f3n e instalaci\u00f3n de cables el\u00e9ctricos.<span style=\"font-size: medium; white-space-collapse: collapse;\"><\/span><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60092-353<\/strong><\/td><td>Instalaciones el\u00e9ctricas en barcos &#8211; Apartado 353: Cables el\u00e9ctricos de campo unipolares y multipolares no radiales con aislamiento s\u00f3lido extruido para tensiones nominales de 1 kV y 3 kV; Enmienda 1.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60092-354<\/strong><\/td><td>Instalaciones el\u00e9ctricas en barcos &#8211; Apartado 354: Cables de alimentaci\u00f3n unipolares y tripolares con aislamiento s\u00f3lido extruido para tensiones nominales de 6 kV (U&lt;(Index)m&gt; = 7,2 kV) a 30 kV (U&lt;(Index)m&gt; = 36 kV).<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60092-376<\/strong><\/td><td>Instalaciones el\u00e9ctricas en barcos &#8211; Apartado 376: Cables para circuitos de control e instrumentaci\u00f3n 150\/250 V (300 V).<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60228<\/strong><\/td><td>Conductores de cables aislados &#8211; Gu\u00eda de los l\u00edmites dimensionales de los conectores circulares.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60331<\/strong><\/td><td>Ensayo de cables el\u00e9ctricos en condiciones de incendio. Integridad del circuito.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60332-1<\/strong><\/td><td>Ensayos de cables el\u00e9ctricos y de fibra \u00f3ptica en condiciones de incendio -Ensayo de propagaci\u00f3n vertical de la llama para un hilo o cable aislado.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60332-3<\/strong><\/td><td>Ensayo de cables el\u00e9ctricos en condiciones de incendio &#8211; Ensayo de propagaci\u00f3n vertical de la llama de alambres o cables agrupados montados verticalmente.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60502-1<\/strong><\/td><td>Cables el\u00e9ctricos con aislamiento extruido y sus accesorios para tensiones asignadas de 1 kV (Um = 1,2 kV) a 30 kV (Um = 36 kV) &#8211; Parte 1: Cables para tensiones asignadas de 1 kV (Um = 1,2 kV) y 3 kV (Um = 3,6 kV) IEC 60754-1 M\u00e9todo para la determinaci\u00f3n de la cantidad de gas \u00e1cido halogenado desprendido durante la combusti\u00f3n de materiales polim\u00e9ricos tomados de los cables.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60754-2<\/strong><\/td><td>Determinaci\u00f3n del grado de acidez (corrosividad) de los gases midiendo el pH y la conductividad.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60793-1<\/strong><\/td><td>Fibra \u00f3ptica.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 60794-1<\/strong><\/td><td>Cables de fibra \u00f3ptica.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>IEC 61034-2<\/strong><\/td><td>Medici\u00f3n de la densidad del humo de cables el\u00e9ctricos que arden en condiciones definidas (LT).<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Normativas para cables marinos (IEC)<\/figcaption><\/figure>\n\n\n\n<div style=\"height:36px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-22825 lazyload\" alt=\"normativas para cables marinos\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/marine-1024x407.png\" data-object-fit=\"cover\"\/><noscript><img decoding=\"async\" width=\"1024\" height=\"407\" class=\"wp-block-cover__image-background wp-image-22825 lazyload\" alt=\"normativas para cables marinos\" src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/marine-1024x407.png\" data-object-fit=\"cover\" srcset=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/marine-1024x407.png 1024w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/marine-300x119.png 300w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/marine-768x305.png 768w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/marine.png 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"top-cable-un-proveedor-global-de-la-industria-naval\"><\/span>TOP CABLE, UN PROVEEDOR GLOBAL DE LA INDUSTRIA NAVAL<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Top Cable es un proveedor global de la industria naval mundial. Toda la gama marina de Top Cable se fabrica de acuerdo con la serie IEC 60092 de normativas para cables marinos y cuenta con la homologaci\u00f3n de clase de las principales agencias internacionales: American Bureau of Shipping (ABS), Bureau Veritas (BV), Det Norske Veritas &amp; Germanischer Lloyd Maritime (DNV GL), y Lloyd&#8217;s Register Marine (LR).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Disponemos de una gama completa de <strong>cables marinos de potencia, control, instrumentaci\u00f3n y baja tensi\u00f3n<\/strong>, disponibles en versiones blindadas y no blindadas y tambi\u00e9n en funci\u00f3n de las prestaciones frente al fuego: ign\u00edfugos y retardantes del fuego, y resistentes al fuego. Todos ellos, cumpliendo con las normativas para cables marinos. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La <a href=\"https:\/\/www.topcable.com\/low-voltage-cables\/marine-cables\/\" target=\"_blank\" rel=\"noreferrer noopener\">gama de cables marinos TOXFREE\u00ae de TOP CABLE<\/a> es la mejor soluci\u00f3n para buques mercantes, cruceros, buques alimentadores, graneleros, petroleros, buques perforadores, flotadores, etc.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-23082 lazyload\" alt=\"\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/adobestock-441369495-1024x683.jpeg\" style=\"object-position:63% 100%\" data-object-fit=\"cover\" data-object-position=\"63% 100%\"\/><noscript><img decoding=\"async\" width=\"1024\" height=\"683\" class=\"wp-block-cover__image-background wp-image-23082 lazyload\" alt=\"\" src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/adobestock-441369495-1024x683.jpeg\" style=\"object-position:63% 100%\" data-object-fit=\"cover\" data-object-position=\"63% 100%\" srcset=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/adobestock-441369495-1024x683.jpeg 1024w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/adobestock-441369495-300x200.jpeg 300w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/adobestock-441369495-768x512.jpeg 768w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2024\/05\/adobestock-441369495.jpeg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:33px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"top-cable-fabricante-y-proveedor-de-confianza-de-cables-marinos\"><\/span>TOP CABLE, FABRICANTE Y PROVEEDOR DE CONFIANZA DE CABLES MARINOS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En Top Cable encontrar\u00e1s un fabricante y proveedor de confianza de cables con las normativas para cables marinos para todas las instalaciones. Nuestra amplia gama de cables marinos abarca desde la selecci\u00f3n o el dise\u00f1o del cable, la gesti\u00f3n del proyecto con nuestros conocimientos t\u00e9cnicos, hasta la log\u00edstica y el servicio posventa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si quieres m\u00e1s informaci\u00f3n sobre nuestra gama de cables marinos o las normativas para cables marinos, ponte en <a href=\"https:\/\/www.topcable.com\/es\/contacto\/\/\" target=\"_blank\" rel=\"noreferrer noopener\">contacto con nosotros hoy mismo<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Los cables marinos se someten a rigurosos procesos de tests y certificaci\u00f3n para garantizar la m\u00e1xima fiabilidad y seguridad de la instalaci\u00f3n. A continuaci\u00f3n repasamos las principales normativas para cables marinos a nivel internacional. Estos cables deben cumplir las normativas internacionales para garantizar la seguridad a bordo. La International Electromechanical Commission (IEC) destaca como la [&hellip;]<\/p>\n","protected":false},"author":32,"featured_media":23076,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[61],"tags":[],"class_list":["post-22843","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-top-cable-2"],"_links":{"self":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts\/22843","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/comments?post=22843"}],"version-history":[{"count":24,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts\/22843\/revisions"}],"predecessor-version":[{"id":32791,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts\/22843\/revisions\/32791"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/media\/23076"}],"wp:attachment":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/media?parent=22843"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/categories?post=22843"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/tags?post=22843"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}