{"id":2538,"date":"2016-06-13T09:48:16","date_gmt":"2016-06-13T09:48:16","guid":{"rendered":"http:\/\/www.topcable.com\/blog-electric-cable\/?p=2538"},"modified":"2025-07-28T09:40:12","modified_gmt":"2025-07-28T09:40:12","slug":"10-aspectos-clave-adicionales-sobre-la-cpr","status":"publish","type":"post","link":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/","title":{"rendered":"10 aspectos clave ADICIONALES SOBRE LA CPR"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left-text counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<label for=\"ez-toc-cssicon-toggle-item-6a35633e637e9\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"ez-toc-title\" style=\"cursor:inherit\">INDEX<\/span>\n<span class=\"ez-toc-cssicon\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #444444;color:#444444\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #444444;color:#444444\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-6a35633e637e9\" checked \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#1-%c2%bfcuales-son-las-clases-de-reaccion-y-resistencia-al-fuego\" >1. \u00bfCu\u00e1les son las clases de reacci\u00f3n y resistencia al fuego?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#i\" >&nbsp;<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#2-%c2%bfcomo-puede-saber-el-usuario-que-un-producto-es-correcto-para-las-aplicaciones-de-cpr\" >2. \u00bfC\u00f3mo puede saber el usuario que un producto es correcto para las aplicaciones de CPR?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#i-2\" >&nbsp;<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#3-para-los-productos-resistentes-al-fuego-%c2%bfcuales-son-las-nuevas-normas-y-regulaciones-que-contribuiran-a-la-cpr\" >3. Para los productos resistentes al fuego, \u00bfCu\u00e1les son las nuevas normas y regulaciones que contribuir\u00e1n a la CPR?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#4-bajo-la-cpr-%c2%bfquien-es-el-fabricante\" >4. Bajo la CPR, \u00bfqui\u00e9n es el fabricante?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#5-%c2%bfcuales-son-las-obligaciones-del-fabricante-bajo-la-cpr\" >5. \u00bfCu\u00e1les son las obligaciones del fabricante bajo la CPR?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#6-%c2%bfes-el-mayorista-responsable-por-la-aplicacion-de-la-cpr\" >6. \u00bfEs el mayorista responsable por la aplicaci\u00f3n de la CPR?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#7-%c2%bfcomo-se-alinearan-las-normas-nacionales-con-la-cpr\" >7. \u00bfC\u00f3mo se alinear\u00e1n las normas nacionales con la CPR?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#8-%c2%bfesta-definida-la-euroclase-eca-con-referencia-eniec-60332-1-2\" >8. \u00bfEst\u00e1 definida la Euroclase ECA con referencia EN\/IEC 60332-1-2?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#9-%c2%bfcomo-afectan-los-requerimientos-de-un-cable-con-la-cpr-que-se-ha-importado-de-fuera-de-la-ue\" >9. \u00bfC\u00f3mo afectan los requerimientos de un cable con la CPR que se ha importado de fuera de la UE?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/es\/10-aspectos-clave-adicionales-sobre-la-cpr\/#10-%c2%bfse-pueden-utilizar-todavia-las-marcas-de-calidad-voluntarias-en-un-producto-marcado-del-ce\" >10. \u00bfSe pueden utilizar todav\u00eda las marcas de calidad voluntarias en un producto marcado del CE?<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1-%c2%bfcuales-son-las-clases-de-reaccion-y-resistencia-al-fuego\"><\/span>1. \u00bfCu\u00e1les son las clases de reacci\u00f3n y resistencia al fuego?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Para la reacci\u00f3n al fuego de los cables, la Directiva 2006\/751\/CE establece diferentes clases de rendimiento denominado <strong>\u00abclases de reacci\u00f3n al fuego frente al rendimiento para cables el\u00e9ctricos\u00bb<\/strong>. Se definen siete clases (A<sub>CA<\/sub>, B1<sub>CA<\/sub>, B2<sub>CA<\/sub>, C<sub>CA<\/sub>, D<sub>CA<\/sub>, E<sub>CA<\/sub>\u00a0y F<sub>CA<\/sub>). <strong>La liberaci\u00f3n de calor y la propagaci\u00f3n de la llama<\/strong> son los principales criterios de clasificaci\u00f3n, pero la <strong>producci\u00f3n de humo, desprendimiento de part\u00edculas y la acidez<\/strong> son otros criterios de clasificaci\u00f3n. <a title=\"clasificaci\u00f3n CPR\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/resumen-de-la-clasificacion-cpr-clases-b2-c-d-y-e\/\" target=\"_blank\" rel=\"noreferrer noopener\">En este post te explicamos con m\u00e1s detalle las diferentes clasificaciones CPR. <\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La resistencia al fuego es un t\u00e9rmino utilizado para describir un cable que se utiliza para asegurar la continuidad de la alimentaci\u00f3n y\/o se\u00f1al de suministro de instalaciones de seguridad. Para la resistencia al fuego de los cables, la Directiva 2000\/367\/CE establece diferentes clases de rendimiento indicados en t\u00e9rminos de una clasificaci\u00f3n basada en el tiempo de supervivencia. Los tiempos son de 15, 30, 60, 90 y 120 minutos en clasificaci\u00f3n P o PH.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"i\"><\/span>&nbsp;<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2-%c2%bfcomo-puede-saber-el-usuario-que-un-producto-es-correcto-para-las-aplicaciones-de-cpr\"><\/span>2. \u00bfC\u00f3mo puede saber el usuario que un producto es correcto para las aplicaciones de CPR?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los siguientes elementos son necesarios para el usuario:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>Conocimientos sobre la Euro Class<\/strong>, solicitada por cualquier normativa nacional para las construcciones\/obras.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>El marcado CE<\/strong> acompa\u00f1ado de la informaci\u00f3n relacionada con la certificaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 <strong>Declaraci\u00f3n de rendimiento del proveedor&nbsp;<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para mayor rendimiento a las clases de fuego (A<sub>CA<\/sub>, B1<sub>CA<\/sub>, B2<sub>CA<\/sub>&nbsp;and C<sub>CA<\/sub>), los cables requieren la evaluaci\u00f3n y verificaci\u00f3n del Constancy of Performance System 1+ (anteriormente el certificado de conformidad). La inspecci\u00f3n inicial de la f\u00e1brica y del control de producci\u00f3n de la f\u00e1brica, as\u00ed como la vigilancia continua de la FPC, incluida la verificaci\u00f3n de las muestras tomadas en la f\u00e1brica. Este sistema de certificaci\u00f3n ayudar\u00e1 a garantizar que los par\u00e1metros clave que afectan a la seguridad en la utilizaci\u00f3n de cables bajo condiciones de fuego est\u00e9n adecuadamente controladas.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2016\/06\/CPR_construction_products_regulation_13_ESP.png\" alt=\"CPR_construction_products_regulation_13_ESP\" class=\"wp-image-2542 lazyload\"\/><noscript><img decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2016\/06\/CPR_construction_products_regulation_13_ESP.png\" alt=\"CPR_construction_products_regulation_13_ESP\" class=\"wp-image-2542 lazyload\" srcset=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2016\/06\/CPR_construction_products_regulation_13_ESP.png 800w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2016\/06\/CPR_construction_products_regulation_13_ESP-768x576.png 768w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2016\/06\/CPR_construction_products_regulation_13_ESP-300x225.png 300w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2016\/06\/CPR_construction_products_regulation_13_ESP-624x468.png 624w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"i-2\"><\/span>&nbsp;<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3-para-los-productos-resistentes-al-fuego-%c2%bfcuales-son-las-nuevas-normas-y-regulaciones-que-contribuiran-a-la-cpr\"><\/span>3. Para los productos resistentes al fuego, \u00bfCu\u00e1les son las nuevas normas y regulaciones que contribuir\u00e1n a la CPR?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>La tabla Euroclass tiene en cuenta todo el comportamiento de los cables durante un incendio<\/strong>, medido din\u00e1micamente contra el tiempo real de las muestras. Este es un importante paso adelante en la seguridad contra incendios y permite a las autoridades nacionales tratar los cables de manera similar a otros productos de construcci\u00f3n ya cubiertos por la CPR. La tabla se convertir\u00e1 en una caracter\u00edstica est\u00e1ndar de los reglamentos de construcci\u00f3n en Europa, aunque lo m\u00e1s probable es que sean aplicados de manera diferente a trav\u00e9s de la UE. De hecho, <strong>cada pa\u00eds<\/strong>, bajo el principio de subsidiariedad, <strong>decidir\u00e1 c\u00f3mo estas clases se utilizan en su construcci\u00f3n<\/strong>. Cabe se\u00f1alar que no es obligatoria la clasificaci\u00f3n para ser introducido en la normativa nacional, algunos pa\u00edses pueden tomar la decisi\u00f3n de abordar esta cuesti\u00f3n en otras formas. Esta tabla se convertir\u00e1 en un punto de referencia, ya que, cualquiera que sea de su aplicaci\u00f3n ser\u00e1 com\u00fan para todos los productos. El nivel de rendimiento de los productos definidos por las clases ser\u00e1 claramente entendido por todos los responsables europeos. Los productos presentados al mercado cumplir\u00e1n con grandes requisitos de prueba, tendr\u00e1n que garantizar que la seguridad de las personas, los animales y los bienes pueden ser protegidos de los riesgos de incendio.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4-bajo-la-cpr-%c2%bfquien-es-el-fabricante\"><\/span>4. Bajo la CPR, \u00bfqui\u00e9n es el fabricante?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El fabricante es la persona que comercializa el producto en el mercado de la UE. Puede ser el fabricante o el importador.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5-%c2%bfcuales-son-las-obligaciones-del-fabricante-bajo-la-cpr\"><\/span>5. \u00bfCu\u00e1les son las obligaciones del fabricante bajo la CPR?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Las obligaciones del fabricante se establecen en el art.11 de la CPR. Antes de colocar un producto en el mercado, cuando est\u00e9 bajo una norma armonizada, el fabricante elaborar\u00e1 una Declaration of Performance (DoP) y estampar\u00e1 el marcado \u00abCE\u00bb. El fabricante, elaborando su DoP, asume la responsabilidad de la conformidad del producto de construcci\u00f3n con el rendimiento declarado. Sobre la base de la informaci\u00f3n contenida en la Declaraton of Performance, el usuario decide comprar, de entre todos los productos disponibles en el mercado, uno que es apropiado para el uso que \u00e9l o ella tiene la intenci\u00f3n de dar al producto y asume toda la responsabilidad por esa decisi\u00f3n. Toda la informaci\u00f3n suministrada en el DoP se obtiene mediante la estricta aplicaci\u00f3n de los m\u00e9todos y criterios establecidos en las normas armonizadas pertinentes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La correcta aplicaci\u00f3n de estos m\u00e9todos y criterios est\u00e1n garantizados por el fabricante del mismo y por la participaci\u00f3n apropiada de un organismo notificado, siguiendo el sistema de aplicaci\u00f3n de la evaluaci\u00f3n y verificaci\u00f3n de constancia de desempe\u00f1o AVCP (Assessment and Verification of Constancy of Performance).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La colocaci\u00f3n del marcado CE sigue el dibujo de la DoP e indica que el fabricante ha seguido estrictamente todos los procedimientos aplicables para la elaboraci\u00f3n de la DoP, que es precisa y confiable.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6-%c2%bfes-el-mayorista-responsable-por-la-aplicacion-de-la-cpr\"><\/span>6. \u00bfEs el mayorista responsable por la aplicaci\u00f3n de la CPR?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El comerciante tiene la responsabilidad de actuar con el debido cuidado para respetar la CPR. En otras palabras, <strong>los distribuidores velar\u00e1n por que el producto, en caso necesario, lleva la marca CE y estar\u00e1 acompa\u00f1ado de los documentos requeridos en la CPR.<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"7-%c2%bfcomo-se-alinearan-las-normas-nacionales-con-la-cpr\"><\/span>7. \u00bfC\u00f3mo se alinear\u00e1n las normas nacionales con la CPR?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cuando existan normas nacionales, deben estar alineados para utilizar las prestaciones dadas las Euroclases. El nivel de el rendimiento real requerido para cualquier aplicaci\u00f3n particular regulado es una cuesti\u00f3n nacional.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"8-%c2%bfesta-definida-la-euroclase-eca-con-referencia-eniec-60332-1-2\"><\/span>8. \u00bfEst\u00e1 definida la Euroclase ECA con referencia EN\/IEC 60332-1-2?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, para las otras clases, no hay ninguna relaci\u00f3n directa entre las existentes basadas en prueba IEC y CPR debido a los m\u00e9todos de prueba diferentes. A pesar de que la estructura b\u00e1sica de la plataforma de prueba es exactamente el mismo, el montaje es diferente y el uso de nuevos par\u00e1metros hace que los resultados no sean comparables.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"9-%c2%bfcomo-afectan-los-requerimientos-de-un-cable-con-la-cpr-que-se-ha-importado-de-fuera-de-la-ue\"><\/span>9. \u00bfC\u00f3mo afectan los requerimientos de un cable con la CPR que se ha importado de fuera de la UE?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Los requerimientos de CPR se aplicar\u00e1n tan pronto como el cable se coloque en el mercado de la UE.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"10-%c2%bfse-pueden-utilizar-todavia-las-marcas-de-calidad-voluntarias-en-un-producto-marcado-del-ce\"><\/span>10. \u00bfSe pueden utilizar todav\u00eda las marcas de calidad voluntarias en un producto marcado del CE?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, se permiten marcas de certificaci\u00f3n voluntaria, pero no debe cubrir el fuego con el rendimiento de cables cubiertos por las CPR.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bfQuieres saber m\u00e1s sobre la&nbsp;CPR ? Te lo resumimos en 4 minutos:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><iframe width=\"1403\" height=\"789\" src=\"https:\/\/www.youtube.com\/embed\/1ZuIVpjp-54\" title=\"CPR | Construction products Regulation | Top Cable\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen=\"\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>1. \u00bfCu\u00e1les son las clases de reacci\u00f3n y resistencia al fuego? Para la reacci\u00f3n al fuego de los cables, la Directiva 2006\/751\/CE establece diferentes clases de rendimiento denominado \u00abclases de reacci\u00f3n al fuego frente al rendimiento para cables el\u00e9ctricos\u00bb. Se definen siete clases (ACA, B1CA, B2CA, CCA, DCA, ECA\u00a0y FCA). La liberaci\u00f3n de calor y [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2542,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[61],"tags":[],"class_list":["post-2538","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-top-cable-2"],"_links":{"self":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts\/2538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/comments?post=2538"}],"version-history":[{"count":7,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts\/2538\/revisions"}],"predecessor-version":[{"id":32753,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/posts\/2538\/revisions\/32753"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/media\/2542"}],"wp:attachment":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/media?parent=2538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/categories?post=2538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/es\/wp-json\/wp\/v2\/tags?post=2538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}