{"id":25174,"date":"2025-05-30T10:00:00","date_gmt":"2025-05-30T10:00:00","guid":{"rendered":"https:\/\/www.topcable.com\/blog-electric-cable\/?p=25174"},"modified":"2025-07-01T14:53:09","modified_gmt":"2025-07-01T14:53:09","slug":"reaction-au-feu","status":"publish","type":"post","link":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/reaction-au-feu\/","title":{"rendered":"Test de r\u00e9action au feu des c\u00e2bles RPC"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">La r\u00e9glementation europ\u00e9enne RPC oblige les fabricants de c\u00e2bles \u00e0 effectuer un test de r\u00e9action au feu s\u00e9v\u00e8re dans des laboratoires officiels. Les r\u00e9sultats officiels de ces tests indiqueront la performance au feu de ces c\u00e2bles, refl\u00e9t\u00e9e dans les classes B2<sub>ca<\/sub>, C<sub>ca<\/sub>, D<sub>ca<\/sub> ou E<sub>ca<\/sub>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le r\u00e8glement RPC, en vigueur depuis le 1er juillet 2016, oblige les fabricants de c\u00e2bles, les distributeurs de c\u00e2bles, les chefs de projet, les architectes, les constructeurs et les installateurs \u00e0 travers l&rsquo;Europe \u00e0 fournir des c\u00e2bles avec le bon classement RPC dans les b\u00e2timents. La nouvelle norme fran\u00e7aise <strong><a title=\"RPC\" href=\"https:\/\/topcable.com\/downloads\/pdf\/FRA\/TopCable_NFC15_100_FRA_9015071032202.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">NF C 15-100<\/a><\/strong>, conform\u00e9ment au r\u00e8glement sur les produits de construction (RPC), inclut des c\u00e2bles offrant de meilleures performances en cas d&rsquo;incendie dans tous les \u00e9tablissements recevant du public (ERP) de toutes cat\u00e9gories et les immeubles de grande hauteur (IGH).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pendant l&rsquo;essai de r\u00e9action au feu, le d\u00e9gagement de chaleur et la propagation de la flamme sont constamment mesur\u00e9s.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left-text counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<label for=\"ez-toc-cssicon-toggle-item-6a6b5c1177775\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"ez-toc-title\" style=\"cursor:inherit\">INDEX<\/span>\n<span class=\"ez-toc-cssicon\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #444444;color:#444444\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #444444;color:#444444\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-6a6b5c1177775\" checked \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/reaction-au-feu\/#parametres-de-lessai-de-reaction-au-feu\" >PARAM\u00c8TRES DE L&rsquo;ESSAI DE R\u00c9ACTION AU FEU<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/reaction-au-feu\/#non-propagation-de-la-flamme\" >NON PROPAGATION DE LA FLAMME<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/reaction-au-feu\/#niveaux-de-classification-supplementaires\" >NIVEAUX DE CLASSIFICATION SUPPL\u00c9MENTAIRES<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/reaction-au-feu\/#quel-cours-de-rpc-est-exige-dans-les-pays-europeens\" >QUEL COURS DE RPC EST EXIG\u00c9 DANS LES PAYS EUROP\u00c9ENS ?<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"parametres-de-lessai-de-reaction-au-feu\"><\/span>PARAM\u00c8TRES DE L&rsquo;ESSAI DE R\u00c9ACTION AU FEU<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>En ce qui concerne la r\u00e9action du c\u00e2ble au contact de la flamme selon le RPC, l&rsquo;essai de r\u00e9action au feu effectu\u00e9 dans le laboratoire d&rsquo;essai suit ces param\u00e8tres :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Norme : EN 50399<\/li>\n\n\n\n<li>Cabine d&rsquo;incendie<\/li>\n\n\n\n<li>\u00c9chelle de c\u00e2ble verticale<\/li>\n\n\n\n<li>Analyseurs de gaz<\/li>\n\n\n\n<li>Br\u00fbleur 20 kW<\/li>\n\n\n\n<li>Taux de d\u00e9gagement de chaleur<\/li>\n\n\n\n<li>Non propagation de la flamme<\/li>\n\n\n\n<li>Production de fum\u00e9e<\/li>\n\n\n\n<li>Retomb\u00e9es de particules<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Vous pouvez voir comment fonctionne le test de r\u00e9action au feu dans la vid\u00e9o suivante.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-3e41869c wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a title=\"r\u00e9cation au feu\" class=\"wp-block-button__link has-azul-boton-background-color has-background wp-element-button\" href=\"https:\/\/www.youtube.com\/watch?v=1ao5ZKtpCts\" target=\"_blank\" rel=\"noreferrer noopener\">VID\u00c9O TEST DE R\u00c9ACTION AU FEU<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"non-propagation-de-la-flamme\"><\/span>NON PROPAGATION DE LA FLAMME<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Parmi les nombreux autres aspects pertinents, les c\u00e2bles B2<sub>ca<\/sub> ne doivent pas propager la flamme sur plus de 1,5 m\u00e8tre. Les c\u00e2bles C<sub>ca<\/sub> ne doivent pas propager la falmme sur plus de 2 m\u00e8tres. Par cons\u00e9quent, l&rsquo;installation de c\u00e2bles B2<sub>ca<\/sub> ou C<sub>ca<\/sub> emp\u00eache un incendie localis\u00e9 de se propager \u00e0 d&rsquo;autres zones par le biais du r\u00e9seau de c\u00e2bles.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-7457 lazyload\" alt=\"R\u00e9action au feu\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2018\/10\/test-fuego-cpr-2.jpg\" data-object-fit=\"cover\"\/><noscript><img decoding=\"async\" width=\"1024\" height=\"577\" class=\"wp-block-cover__image-background wp-image-7457 lazyload\" alt=\"R\u00e9action au feu\" src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2018\/10\/test-fuego-cpr-2.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2018\/10\/test-fuego-cpr-2.jpg 1024w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2018\/10\/test-fuego-cpr-2-300x169.jpg 300w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2018\/10\/test-fuego-cpr-2-768x433.jpg 768w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2018\/10\/test-fuego-cpr-2-624x352.jpg 624w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\" style=\"background-color:#725c24\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"niveaux-de-classification-supplementaires\"><\/span>NIVEAUX DE CLASSIFICATION SUPPL\u00c9MENTAIRES<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>En outre, le RPC \u00e9tablit trois niveaux de classification suppl\u00e9mentaires :<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1) la quantit\u00e9 de fum\u00e9e produite, indiqu\u00e9e par la classification suivante : s1a, s1b, s2 ou s3.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2) les particules inflammables tombant du c\u00e2ble pendant la combustion, indiqu\u00e9es par d0, d1 et d2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3) le niveau d&rsquo;acidit\u00e9 des fum\u00e9es produites lors de la combustion, class\u00e9 a1, a2 et a3.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ces \u00e9valuations suppl\u00e9mentaires sont essentielles en mati\u00e8re de s\u00e9curit\u00e9 incendie.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-1024x660.png\" alt=\"\" class=\"wp-image-15455 lazyload\"\/><noscript><img decoding=\"async\" width=\"1024\" height=\"660\" src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-1024x660.png\" alt=\"\" class=\"wp-image-15455 lazyload\" srcset=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-1024x660.png 1024w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-300x193.png 300w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-768x495.png 768w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-1536x990.png 1536w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr-624x402.png 624w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2023\/10\/cpr-fr.png 1550w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"quel-cours-de-rpc-est-exige-dans-les-pays-europeens\"><\/span>QUEL COURS DE RPC EST EXIG\u00c9 DANS LES PAYS EUROP\u00c9ENS ?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les r\u00e9glementations nationales prescrivent des classes sp\u00e9cifiques en fonction de l&rsquo;environnement et des r\u00e8gles d&rsquo;installation. Dans la plupart des pays europ\u00e9ens, la classe Cca est exig\u00e9e dans les lieux \u00e0 forte densit\u00e9 de personnes et d&rsquo;\u00e9quipements importants, tels que les bureaux, les \u00e9coles, les h\u00f4tels, les h\u00f4pitaux, etc.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Top Cable propose une large gamme de c\u00e2bles aux performances RPC les plus \u00e9lev\u00e9es. Pour plus d&rsquo;informations, veuillez <a title=\"contact\" href=\"https:\/\/www.topcable.com\/fr\/contact\/\/\" target=\"_blank\" rel=\"noreferrer noopener\">contacter votre repr\u00e9sentant Top Cable<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>La r\u00e9glementation europ\u00e9enne RPC oblige les fabricants de c\u00e2bles \u00e0 effectuer un test de r\u00e9action au feu s\u00e9v\u00e8re dans des laboratoires officiels. Les r\u00e9sultats officiels de ces tests indiqueront la performance au feu de ces c\u00e2bles, refl\u00e9t\u00e9e dans les classes B2ca, Cca, Dca ou Eca. Le r\u00e8glement RPC, en vigueur depuis le 1er juillet 2016, [&hellip;]<\/p>\n","protected":false},"author":32,"featured_media":32239,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[61],"tags":[],"class_list":["post-25174","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-top-cable-2"],"_links":{"self":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/posts\/25174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/comments?post=25174"}],"version-history":[{"count":8,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/posts\/25174\/revisions"}],"predecessor-version":[{"id":32018,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/posts\/25174\/revisions\/32018"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/media\/32239"}],"wp:attachment":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/media?parent=25174"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/categories?post=25174"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/fr\/wp-json\/wp\/v2\/tags?post=25174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}