{"id":32929,"date":"2025-09-30T13:13:59","date_gmt":"2025-09-30T13:13:59","guid":{"rendered":"https:\/\/www.topcable.com\/blog-electric-cable\/?p=32929"},"modified":"2026-07-02T06:59:09","modified_gmt":"2026-07-02T06:59:09","slug":"bs-5839-compliant-cable","status":"publish","type":"post","link":"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/","title":{"rendered":"How to choose BS 5839\u00a0compliant fire alarm cable (with TOXFREE\u00ae benefits)"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>All UK public and commercial buildings must have a method of detecting fires and alerting people on-site. Choosing the best fire alarm cable for BS 5839&nbsp;compliance&nbsp;-and EN 50525- means integrating standards, performance, and safety. This cable is designed to comply with the regulations of Fire Detection and Alarm systems, and it is highly recommended to be installed in public places such as hospitals, datacentres, airports, high rise buildings and similar.&nbsp;<\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover is-light\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-33856 size-full lazyload\" alt=\"\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2025\/09\/fire-alarm-480x296-1.webp\" data-object-fit=\"cover\"\/><noscript><img decoding=\"async\" width=\"480\" height=\"296\" class=\"wp-block-cover__image-background wp-image-33856 size-full lazyload\" alt=\"\" src=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2025\/09\/fire-alarm-480x296-1.webp\" data-object-fit=\"cover\" srcset=\"https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2025\/09\/fire-alarm-480x296-1.webp 480w, https:\/\/www.topcable.com\/blog-electric-cable\/wp-content\/uploads\/2025\/09\/fire-alarm-480x296-1-300x185.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/><\/noscript><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\" style=\"background-color:#dbc9d0\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\"><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left-text counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<label for=\"ez-toc-cssicon-toggle-item-6a731e05a9134\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"ez-toc-title\" style=\"cursor:inherit\">INDEX<\/span>\n<span class=\"ez-toc-cssicon\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #444444;color:#444444\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #444444;color:#444444\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-6a731e05a9134\" checked \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#key-takeaways-about-bs-5839\" >KEY TAKEAWAYS ABOUT BS 5839<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#what-is-a-fire-alarm-cable-%f0%9f%9a%a8\" >WHAT IS A FIRE ALARM CABLE? &nbsp;\ud83d\udea8&nbsp;<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#what-are-the-types-of-fire-alarm-cables-%f0%9f%94%a5\" >WHAT ARE THE TYPES OF FIRE ALARM CABLES? \ud83d\udd25<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#fire-alarm-cables-a-comparison-table\" >FIRE ALARM CABLES: A COMPARISON TABLE<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#how-to-choose-the-right-fire-alarm-cable\" >HOW TO CHOOSE THE RIGHT FIRE ALARM CABLE?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#cable-selection-checklist\" >CABLE SELECTION CHECKLIST<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#top-cable-the-best-manufacturer-and-supplier-for-fire-alarm-cables\" >TOP CABLE, THE BEST MANUFACTURER AND SUPPLIER FOR FIRE ALARM CABLES<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#frequently-asked-questions-faq\" >FREQUENTLY ASKED QUESTIONS (FAQ)<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#whats-special-about-toxfree%c2%ae-fire-alarms-z1oz1-k\" >What\u2019s special about TOXFREE\u00ae FIRE ALARMS Z1OZ1-K?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#do-i-need-to-use-red-cables-only\" >Do I need to use red cables only?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.topcable.com\/blog-electric-cable\/bs-5839-compliant-cable\/#what-is-the-cpr-rating-in-fire-alarm-cables\" >What is the CPR rating in fire alarm cables?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"key-takeaways-about-bs-5839\"><\/span>KEY TAKEAWAYS ABOUT BS 5839<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a title=\"BS 5839\" href=\"https:\/\/knowledge.bsigroup.com\/products\/fire-detection-and-fire-alarm-systems-for-buildings-design-installation-commissioning-and-maintenance-of-systems-in-non-domestic-premises-code-of-practice\" target=\"_blank\" rel=\"noreferrer noopener\">BS 5839 demands fire alarm cables<\/a> tested to strict standards.<\/li>\n\n\n\n<li>Low smoke, zero halogen (LSZH) cable construction drastically reduces toxic gas and smoke emission to protect people and property.<\/li>\n\n\n\n<li><a title=\"Z1OZ1-K\" href=\"https:\/\/www.topcable.com\/cable\/toxfree-zh-alarms-z1oz1-k-as\/\" target=\"_blank\" rel=\"noreferrer noopener\">TOXFREE\u00ae FIRE ALARMS Z1OZ1-K<\/a> and its fire-resistant version Z1OZ1-K (AS+) from Top Cable, offer outstanding CPR-rated safety, flexibility, EMI interference and compliance with leading fire and smoke emission standards.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"what-is-a-fire-alarm-cable-%f0%9f%9a%a8\"><\/span>WHAT IS A FIRE ALARM CABLE?<strong> <\/strong>&nbsp;\ud83d\udea8&nbsp;<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Fire alarm cables are specially designed for fire alarms and safety systems. These systems safeguard buildings by constantly monitoring for fire risks, ensuring rapid alerts so people can act quickly in a fire emergency.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fire alarm cable reliably transmits signals from sensors and manual pull stations to the control panel and notification devices, enabling fast system response during a fire. These cables typically feature copper conductors with LSZH insulation and fire-retardant outer sheath for fire, toxic gases, smoke, and droplets resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The cable screen ensures reliable signal transmission, which is crucial in critical applications. This screen safeguards against EMI and RFI, making these conductors ideal for environments where electronic interference is prevalent.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"what-are-the-types-of-fire-alarm-cables-%f0%9f%94%a5\"><\/span>WHAT ARE THE TYPES OF FIRE ALARM CABLES? \ud83d\udd25<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For fire alarm systems, you can select between <a title=\"fire alarm cable\" href=\"https:\/\/www.topcable.com\/cable\/toxfree-zh-alarms-z1oz1-k-as\/\" target=\"_blank\" rel=\"noreferrer noopener\">standard fire alarm cable<\/a> and enhanced fire-resistant cable, both designed for compliance with relevant safety standards. The choice depends on specific application needs and the required level of circuit integrity during a fire event<strong>.<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Used mostly in low-voltage settings, fire alarm cables are often supplied as two-core cables, with popular sizes including 2&#215;1,5 mm2 and 2&#215;2,5 mm<sup>2<\/sup>. Distinct red insulation helps easy identification and compliant installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"fire-alarm-cables-a-comparison-table\"><\/span>FIRE ALARM CABLES: A COMPARISON TABLE<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Each fire alarm cable in this comparison table will help you select the optimal solution for your safety requirements.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td><\/td><td><strong>TOXFREE\u00ae FIRE ALARMS <\/strong><br><strong>Z1OZ1-K<\/strong><\/td><td><strong>TOXFREE\u00ae FIRE ALARMS<\/strong><br><strong>Z1OZ1-KZ1OZ1-K (AS+)<\/strong><br><strong>Enhanced Fire-Resistant<\/strong><\/td><td><strong>Typical standard fire <\/strong><br><strong>alarm cable<\/strong><\/td><\/tr><tr><td><strong>Compliance<\/strong><\/td><td>BS 5839, EN 50575,&nbsp;<br>CPR Cca<\/td><td>BS 5839, EN 50575,&nbsp;<br>CPR Cca<\/td><td>BS 5839, lower CPR<\/td><\/tr><tr><td><strong>Voltage rating<\/strong><\/td><td>300\/500 V<\/td><td>300\/500 V<\/td><td>300\/500 V<\/td><\/tr><tr><td><strong>Fire grade<\/strong><\/td><td>Standard<\/td><td>Enhanced (PH120)<\/td><td>Standard<\/td><\/tr><tr><td><strong>Smoke\/Acidity\/Droplets \/ light transmittance<\/strong><\/td><td>LSZH:&nbsp;Cca s1a, d1, a1<br>Light transmittance &gt;80%<\/td><td>LSZH:&nbsp;Cca s1a, d1, a1<br>Light transmittance &gt;80%<\/td><td>Basic LSZH or PVC<\/td><\/tr><tr><td><strong>Cable conductor<\/strong><\/td><td>Copper Class 5 (&nbsp;flexible)<\/td><td>Copper Class 5 (&nbsp;flexible)<\/td><td>Copper Class 2<br>Copper Class 5 (flexible)<\/td><\/tr><tr><td><strong>Cable insulation<\/strong><\/td><td>LSZH special polyolefin<\/td><td>Mica tape + LSZH special polyolefin<\/td><td>PVC or LSZH insulation<\/td><\/tr><tr><td><strong>Cable screen<\/strong><\/td><td>Overlapping aluminium polyester tape screen 100% coverage + tinned copper drain wire<\/td><td>Overlapping aluminium polyester tape screen 100% coverage + tinned copper drain wire<\/td><td>Sometimes none<\/td><\/tr><tr><td><strong>Cable outer sheath<\/strong><\/td><td>LSZH fire retardant polyolefin<\/td><td>LSZH fire retardant polyolefin<\/td><td>PVC or LSZH outer sheath<\/td><\/tr><tr><td><strong>Cable &nbsp;colour<\/strong><\/td><td>Red<\/td><td>Red<\/td><td>Red or white<\/td><\/tr><tr><td><strong>M\u00ednimum bending radius<\/strong><\/td><td>10x cable diameter<\/td><td>10x cable diameter<\/td><td>6x cable diameter<\/td><\/tr><tr><td><strong>Max Temp<\/strong><\/td><td>70\u00b0C operation, 160\u00b0C short-circuit, -40\u00ba minimum service<\/td><td>70\u00b0C operation, 160\u00b0C short-circuit, -40\u00ba minimum service<\/td><td>70\u00b0C operation<\/td><\/tr><tr><td><strong>Special Benefits<\/strong><\/td><td>Flexible, easy to install, EMI interference, meter marking<\/td><td>Fire resistant cable, flexible, easy to install, EMI interference, meter marking<\/td><td>Basic compliance<\/td><\/tr><tr><td><strong>Application<\/strong><\/td><td>Fire alarms\/detection<\/td><td>Emergency circuits, high-risk<br>Fire alarms\/detection<\/td><td>Fire alarms\/detection<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"how-to-choose-the-right-fire-alarm-cable\"><\/span>HOW TO CHOOSE THE RIGHT FIRE ALARM CABLE?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Consider cable specifications based on the requirements of the fire alarm system,&nbsp;including: conductor size, insulation, screen and outher&nbsp;sheath (PVC or LSZH), fire resistance CPR rating and the cable flexibility, specially in tight spaces. Lastly, ensure that the cable meets relevant testing and certification standards.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"cable-selection-checklist\"><\/span>CABLE SELECTION CHECKLIST<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select cable with certified LSZH insulation and outer sheath.<\/li>\n\n\n\n<li>Confirm CPR rating (minimum C<sub>ca<\/sub>-s1a, d1, a1).<\/li>\n\n\n\n<li>Check conductor size (minimum 2 mm\u00b2 copper, preferably class 5 flexible for easy installation).<\/li>\n\n\n\n<li>Choose fire-resistant enhanced grade for hospitals, data centres, airports, multi-storey, or phased evacuation buildings.<\/li>\n\n\n\n<li>Use screened cable for signal reliability.<\/li>\n\n\n\n<li>Only install with certified fire-resistant supports\/junction boxes.<\/li>\n\n\n\n<li>Keep fire alarm cable segregated from non-fire alarm circuits.<\/li>\n\n\n\n<li>Ensure meter-by-meter marking for traceability.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"top-cable-the-best-manufacturer-and-supplier-for-fire-alarm-cables\"><\/span>TOP CABLE, THE BEST MANUFACTURER AND SUPPLIER FOR FIRE ALARM CABLES<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you want to achieve the long-term performance of your alarm systems with <strong>reliable&nbsp;fire&nbsp;alarm cables<\/strong>, Top Cable is your preferred choice.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact Top Cable today for a <a title=\"contact\" href=\"https:\/\/www.topcable.com\/contact\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request for Quote for TOXFREE\u00ae FIRE ALARMS Z1OZ1-K or Fire-resistant&nbsp; TOXFREE\u00ae FIRE ALARMS Z1OZ1-K (AS+) cable.<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"frequently-asked-questions-faq\"><\/span>FREQUENTLY ASKED QUESTIONS (FAQ)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list \">\n<div id=\"faq-question-1758192566102\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question \"><span class=\"ez-toc-section\" id=\"whats-special-about-toxfree%c2%ae-fire-alarms-z1oz1-k\"><\/span>What\u2019s special about TOXFREE\u00ae FIRE ALARMS Z1OZ1-K?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"rank-math-answer \">\n\n<p>It\u2019s flexible, LSZH, CPR Cca-s1a, d1, a1 rated, and provides 100% screening for reliable signal transmission and minimal smoke\/toxic emissions.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1758192592644\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question \"><span class=\"ez-toc-section\" id=\"do-i-need-to-use-red-cables-only\"><\/span>Do I need to use red cables only?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"rank-math-answer \">\n\n<p>Red is recommended to ensure clear identification during installation and life safety compliance.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1758192614761\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question \"><span class=\"ez-toc-section\" id=\"what-is-the-cpr-rating-in-fire-alarm-cables\"><\/span>What is the CPR rating in fire alarm cables?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<div class=\"rank-math-answer \">\n\n<p>CPR (Construction Product Regulation) measures fire performance of construction products. Look for<a href=\"https:\/\/www.topcable.com\/blog-electric-cable\/summary-of-cpr-classification-classes-b2-c-d-and-e\/\" target=\"_blank\" rel=\"noreferrer noopener\"> C<sub>ca<\/sub>-s1a, d1, a1 cables<\/a> to ensure low smoke\/toxicity and proven safety por people and property.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>All UK public and commercial buildings must have a method of detecting fires and alerting people on-site. Choosing the best fire alarm cable for BS 5839&nbsp;compliance&nbsp;-and EN 50525- means integrating standards, performance, and safety. This cable is designed to comply with the regulations of Fire Detection and Alarm systems, and it is highly recommended to [&hellip;]<\/p>\n","protected":false},"author":32,"featured_media":32940,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[588],"tags":[],"class_list":["post-32929","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-top-cable-en"],"_links":{"self":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/posts\/32929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/comments?post=32929"}],"version-history":[{"count":4,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/posts\/32929\/revisions"}],"predecessor-version":[{"id":33861,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/posts\/32929\/revisions\/33861"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/media\/32940"}],"wp:attachment":[{"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/media?parent=32929"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/categories?post=32929"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.topcable.com\/blog-electric-cable\/wp-json\/wp\/v2\/tags?post=32929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}