Cable > TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

TOPDRIVE® VFD (EMC)
ROZ1-K 0,6/1kV

Flexible LSZH screened cable for Variable Frequency Drive (VFD) cables .
ACCORDING TO: IEC 60502-1., IEC 60092-353.

TOPDRIVE® VFD ROZ1-K cable has been specially designed for VFD Motors and where it is necessary to limit the effects of electromagnetic interference.

Screen 100% shielding coverage
For VFD applications
EMI protection

Typical applications of
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

Select...
Variable Frequency Drive Motors Industrial facilities Fixed installations
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable is specifically engineered to suppress capacitive leakage currents and dampen reflected wave phenomena, ensuring reliable motor operation and protecting against damaging voltage spikes. A 3+3 configuration in a VFD cable utilizes three main power conductors alongside three symmetrically arranged grounding conductors, which provides a balanced impedance path for common-mode currents to effectively cancel out electromagnetic interference.
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cables excel in industrial facilities by minimizing electromagnetic noise emissions through superior symmetrical shielding and their flame-retardant, halogen-free design significantly reduces smoke and toxic gas release during a fire, enhancing both operational integrity and personnel safety.
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable ensure long-term stability against thermal aging and mechanical stress, guaranteeing sustained performance and reliability over the lifespan of a fixed installation.
Variable Frequency Drive Motors
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable is specifically engineered to suppress capacitive leakage currents and dampen reflected wave phenomena, ensuring reliable motor operation and protecting against damaging voltage spikes. A 3+3 configuration in a VFD cable utilizes three main power conductors alongside three symmetrically arranged grounding conductors, which provides a balanced impedance path for common-mode currents to effectively cancel out electromagnetic interference.
Industrial facilities
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cables excel in industrial facilities by minimizing electromagnetic noise emissions through superior symmetrical shielding and their flame-retardant, halogen-free design significantly reduces smoke and toxic gas release during a fire, enhancing both operational integrity and personnel safety.
Fixed installations
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable ensure long-term stability against thermal aging and mechanical stress, guaranteeing sustained performance and reliability over the lifespan of a fixed installation.

Resources for engineers

TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV Technical datasheet Download file
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV DoP Download file
TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

Technical specifications

Application

TOPDRIVE® VFD ROZ1-K cable has been designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI). This is a flexible cable for fixed insatllations, for variable speed motors or pumps.

Construction

Conductor

Copper, class 5 (flexible) conductor.

Protective conductor

The ground conductor is divided into three conductors; the equivalent cross-section is approximately 50% of the section of the phase conductor.
For 4G cables, ground conductor has the same cross-section as the phase conductors.

Insulation

XLPE insulation.
The standard identification of insulated conductors is the following:
3x + 3G Grey + Brown + Black + Green/yellow (3 G) (from 6 mm2 onwards).
4 G Grey + Brown + Black + Green/yellow (up to 4 mm2).

Assembly of cores

For 3 x + 3 G cables, the three phase conductors are cabled helically with the three protective conductors distributed in the interstices.
For 4 G cables, the three phase conductors and protection conductor are cabled helically.

Screen

Overlapping aluminium-polyester tape screen with 100% coverage + tinned copper drain wire.

Outer sheath

Polyolefin LSZH outer sheath.

Standards / Compliance

ACCORDING TO: IEC 60502-1., IEC 60092-353.

Standards and approvals

  • BUREAU VERITAS.
  • ABS.
  • DNV-GL.
  • LLOYD’S REGISTER
  • RoHS
  • CE

Construction Products Regulation

  • Cca-s1a, d1, a1.

 

Disclaimer
The information displayed on this website is provided for reference purposes only and is not legally binding. Specifications, values, and technical data may be subject to change without notice. To obtain verified and up-to-date technical data for a specific cable, please download Top Cable’s official Technical Specification in PDF format. The PDF document constitutes the sole authoritative source of product data.

 

Characteristics

Electrical performance 0,6/1kV
Thermal performance Maximum conductor temperature: 90ºC. Maximum short-circuittemperature: 250ºC (max. 5 s). Maximum ambient temperature: 60 ºC. Minimum installation and handling temperature: 0 °C. Minimum service temperature: -40ºC (fixed and protected installations).
Fire performance Flame non-propagation according to EN 60332-1 / IEC 60332-1. Fire non-propagation according to EN 60332-3 / IEC 60332-3 and EN 50399. Reaction to fire CPR: Cca-s1a, d1, a1 according to EN 50575. LSZH (Low Smoke Zero Halogen) according to IEC 60754-1. Low corrosive gases emission according to EN 60754-2 / IEC 60754-2. Low smoke emission according to EN 61034 / IEC 61034:Light transmittance > 80%.
Mechanical performance Minimum bending radius: x10 cable diameter. Impact resistance: AG2 Medium severity.
Environmental performance Chemical & Oil resistance: Acceptable. UV resistant according to EN 50618. Water resistance: AD5 Jets.
Installation conditions Being very performant cables there are, however, certain precautions that must be taken into account during installation: - Always respect the bending radius of the cable. Radius below the minimums indicated can cause damage or breakage in the outer sheath. - Precautions design of the laying. It is necessary that the laying of the cable is done in a careful way, taking care not to damage the outer sheath in irregular areas, sharp edges, etc. - Fixings/Fastenings. Adapt fastenings so that the cable adopts a natural position in the laying to avoid stress concentration in the outer sheath. Allow a certain degree of freedom of movement in order to absorb possible movements produced by temperature variations. Open Air Buried In conduit
Other Meter by meter marking.

Why choose our TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

  • cable icon

    As cable manufacturers, we ensure cost-effective premium quality and lasting performance.

  • laboratory icon

    Our in-house labs guarantee rigorous cable quality, reliability, and standards compliance.

  • global icon

    Global cable delivery solutions—expert logistics for seamless supply.

  • logistic icon

    Full cable stock, ready for fast delivery- shortest lead times.
    Largest European stockholding.

  • EPD icon

    EPD-certified cables: Sustainable manufacturing for your Scope 3 success.

  • client support icon

    Expert, friendly and professional sales team offering a fast & efficient customer service. Global customers are welcome!

Need expert advice, a custom solution, or an RFQ?

FAQ's TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

The TOPDRIVE® VFD EMC ROZ1-K is Top Cable’s cable for motor supply with variable frequency drives (VFD). It incorporates a screen and special filler to reduce electromagnetic emissions. It supports 0.6/1 kV and temperatures up to 90°C. Used in industrial automation and motor control.

Top Cable’ s TOPDRIVE® ROZ1-K / 2XSL(ST)CH cable design is the one with the highest performance, favouring earth leakage and avoiding the effect of voltage peaks:

Flexible copper conductor (class 5), which gives the cable maximum flexibility.
Arrangement of conductors and earth three plus three (3C+3G) to avoid current leakage through earth.
Cross-linked polyethylene insulation (XLPE) with performance far superior to PVC.
Double aluminium-polyester screen that offers 100% shielding and thus prevents the emission of electromagnetic waves from our cable to the rest of the equipment.
Tinned copper mesh, with anti-corrosion features and better installation.
Halogen-free outer sheath (LSZH) with the highest CPR classification (Cca – s1a, d1, a1) with low emission of fumes and corrosive gases in case of fire to protect people and equipment.

To avoid voltage peaks, we should use a cable with XLPE insulation (90ºC) instead of one with PVC insulation (70ºC). In addition, the dielectric coefficient of XLPE (2.3) is much lower than that of PVC (7.4), which also reduces the capacitive effect and therefore the magnitude of the reflected waves.

As mentioned above, a cable with an inadequate shield (or no shield) can act as an antenna and be a source of radiated emissions. RV, RV-K, or RZ1-K cables do not guarantee electromagnetic compatibility and impedance matching, and are therefore not suitable for powering VFD motors.

Similarly, it is not advisable to install single core cables, even if they are shielded, as it is necessary to compensate for inductions and respect the symmetrical configuration of the 3C+3G phases.

Here is the PDF of the summary technical specification of the TOPDRIVE® R0Z1-K cable. If you need to consult additional technical aspects of this cable, such as its maximum admissible current or voltage drop, please contact us.

At Top Cable you will get the highest quality cables, with the best prices and the best service for TOPDRIVE® R0Z1-K rubber electrical cable drums and spools. Contact us.

The standardised identification of the insulated conductors of the TOPDRIVE® R0Z1-K cable is as follows:
3 x + 3 G: Grey + brown + black + Yellow/Green (3G) (from 6 mm2).
4 G : Grey + brown + black + Yellow/Green (up to 4 mm2).

Flame non-propagation according to UNE-EN 60332-1 / IEC 60332-1.
Fire non-propagation according to UNE-EN 60332-3 / IEC 60332-3 and EN 50399.
CPR reaction to fire: Cca-s1a, d1, a1, according to EN 50575.
Halogen-free according to UNE-EN 60754-1 / IEC 60754-1.
Low emission of corrosive gases according to UNE-EN 60754-2 / IEC 60754-2.
Low smoke emission according to UNE-EN 61034 / IEC 61034:
Light transmittance > 80%.

TOPDRIVE® R0Z1-K cable has been designed according to the IEC 60502-1 / IEC 60092-353 reference standard and complies with the European CPR (Construction Products Regulation) Cca – s1a, d1, a1. You can consult the Declaration of Performance (DoP) at this link. In addition, the TOPDRIVE® R0Z1-K cable is CE / UKCA / BUREAU VERITAS / DNV-GL / ABS /LLOYD’S REGISTER / RoHS /.

Certain precautions must be taken during installation:

Always respect the bending radius of the cable. Radii smaller than the minimum indicated may cause damage or breakage to the outer sheath.
Adequacy of the laying. The cable must be laid carefully, taking care not to damage the cover in irregular areas, sharp edges, etc.
Fixings/Fastenings. Adapt the fixings so that the cable adopts a natural position in the laying to avoid stress concentration on the roof. Allow a certain degree of freedom of movement and avoid excessively tight cable ties.

A Variable Frequency Drive (VFD) is a system for controlling the rotational speed of an alternating current (AC) motor by controlling the power frequency supplied to the motor.

An electric motor rotates its rotor according to the parameters achieved by the voltage and frequency of the electrical power supplied to the motor. Internationally, there are different mains voltages, such as 400 V (three-phase), 380 V (three-phase), etc., and frequencies of 50 or 60 Hertz. By varying the voltage and/or frequency, the performance of the motor, including the speed, varies. It is usually difficult to change the voltage or frequency without auxiliary equipment.

To vary the voltage and frequency effectively, a variable frequency drive is used. Normal power is supplied to the VFD and the output of the VFD is fed to the electric motor. The VFD has controls that can be adjusted to control the speed of the motor.

A VFD provides precise control of the speed and torque of an AC motor through pulse width modulation (PWM). In a VFD system, it is critical to choose the right cable for best performance, maximum energy efficiency and long life.

Questions? We’ll help you find a solution.