The Marine armoured fire resistant instrumentation cable.
ACCORDING TO: IEC 60092-376

The Toxfree® Marine XOxTCuZ1-K (AS+) cable with zero halogens is a safety instrumentation and telecomunication cable.

Marine cable
Fire resistant cable
ABS | DNV-GL | Bureau Veritas certified

Typical applications of
TOXFREE® MARINE XOxZ1-K (AS+) XOxTCuZ1-K (AS+)

Select...
Fishing vessels Merchant vessels Cruise ships & Yachts
TOXFREE® MARINE XOxZ1-K (AS+) XOxTCuZ1-K (AS+) cables excel as the premier choice for marine cable applications with extra fire-resistance properties. They offer superior saltwater resistance, and durability for harsh maritime environments
TOXFREE® MARINE cables excel as the premier choice for power, control, instrumentation, and low-voltage applications.
Marine shipbuilding cables for cruise ships and yachts require premium safety and comfort. These cables are fully certified by ABS, DNV-GL, and Lloyd’s Register.
Fishing vessels
TOXFREE® MARINE XOxZ1-K (AS+) XOxTCuZ1-K (AS+) cables excel as the premier choice for marine cable applications with extra fire-resistance properties. They offer superior saltwater resistance, and durability for harsh maritime environments
Merchant vessels
TOXFREE® MARINE cables excel as the premier choice for power, control, instrumentation, and low-voltage applications.
Cruise ships & Yachts
Marine shipbuilding cables for cruise ships and yachts require premium safety and comfort. These cables are fully certified by ABS, DNV-GL, and Lloyd’s Register.

Resources for engineers

TOXFREE® MARINE XOxZ1-K (AS+) XOxTCuZ1-K (AS+) Technical datasheet Download file
TOXFREE® MARINE XOxZ1-K (AS+) XOxTCuZ1-K (AS+)

Technical specifications

Application

The Toxfree® Marine XOxTCuZ1-K (AS+) and XOxTCuZ1-K (AS+) cable with halogen frees is a safety instrumentation and telecommunication cable.
It is fire resistant and specially designed to continue transmitting information/data in case of fire. For this reason, it is recommended for use in public places and marine applications.

Construction

Insulation

Mica Tape + XLPE.
The standard identification of insulated conductors is the following:
Pair White + Blue (each core numbered with the pair number).
Other colours available on request.

Assembly of cores

Stranded conductors in pairs

Individual screen

Overlapping aluminium-polyester tape screen with 100% coverage + tinned copper drain wire applied over the assembled cores.

Assembly of pairs

Cabled in concentric layers.

Colective screen

Overlapping aluminium-polyester tape screen with 100% coverage + tinned copper drain wire applied over the assembled pairs.
Only for XO2TCuZ1-K (AS+) cables, the tinned copper drain wire will be removed, and the aluminium side of the tape will put in contact with the braid armour.

Braid armour

Tinned copper wire braid armour over the collective screen.

Outer sheath

Polyolefin LSZH.
Orange colour.
Not toxic and fire retardant and fire resistant.

Standards / Compliance

ACCORDING TO: IEC 60092-376

Standards and approvals

  • CE
  • BUREAU VERITAS.
  • ABS.
  • DNV-GL.
  • RoHS.

 

Disclaimer
The information displayed on this website is provided for reference purposes only and is not legally binding. Specifications, values, and technical data may be subject to change without notice. To obtain verified and up-to-date technical data for a specific cable, please download Top Cable’s official Technical Specification in PDF format. The PDF document constitutes the sole authoritative source of product data.

 

Characteristics

Electrical performance 150/250V
Thermal performance Maximum conductor temperature: 90ºC. Maximum short-circuittemperature: 250ºC (max. 5 s). Minimum service temperature: -40ºC (fixed installations). Lowest installation temperature: -15ºC.
Fire performance Flame non-propagation according to EN 60332-1 and IEC 60332-1. Fire non-propagation according to IEC 60332-3-22. Fire resistant according to EN 60331-21 (90 minutes at 750ºC). LSZH (Low Smoke Zero Halogen) according to EN 60754-1 and IEC 60754-1. Low smoke emission according to EN 61034 and IEC 61034. Light transmittance > 60%. Low corrosive gases emission according to UNE-EN 60754-2 and IEC 60754-2.
Mechanical performance Minimum bending radius: 4 x cable diameter <= 25mm. Minimum bending radius: 6 x cable diameter. Impact resistance: AG3 High severity.
Environmental performance Chemical & Oil resistance: Acceptable. UV resistant according to EN 50618. AD6 waves
Installation conditions Open Air. In conduit on a bulkhead On a bulkhead
Other Meter by meter marking.

Why choose our TOXFREE® MARINE XOxZ1-K (AS+) XOxTCuZ1-K (AS+)

  • cable icon

    As cable manufacturers, we ensure cost-effective premium quality and lasting performance.

  • laboratory icon

    Our in-house labs guarantee rigorous cable quality, reliability, and standards compliance.

  • global icon

    Global cable delivery solutions—expert logistics for seamless supply.

  • logistic icon

    Full cable stock, ready for fast delivery- shortest lead times.
    Largest European stockholding.

  • EPD icon

    EPD-certified cables: Sustainable manufacturing for your Scope 3 success.

  • client support icon

    Expert, friendly and professional sales team offering a fast & efficient customer service. Global customers are welcome!

Need expert advice, a custom solution, or an RFQ?

Questions? We’ll help you find a solution.