TOXFREE PLUS 331 ZH RZ1-K (AS+)

LSZH and fire resistant power cable, for emergency circuits.


TOXFREE Plus 331 ZH RZ1-K AS+ is a fire resistant cable, specially designed to ensure the power supply to emergency circuits in the event of fire. During a fire you need critical circuits to work for life safety (signaling lights, fume extractors, acustic alarms, water pumps, etc) and a secure plant shutdown. For this reason, its use is highly recommended in public places such as: hospitals, tunnels, offices, production plants, laboratories, hotels, etc.

TOXFREE PLUS 331 ZH RZ1-K AS+ cable performance

Electrical performance

LOW VOLTAGE 0,6/1kV

Standard

IEC 60502-1 / UNE 211025

Approvals

CE

RoHS

Thermal performance

Maximum service temperature: 90ºC.

Maximum short-circuit temperature: 250ºC (max. 5 s).

Minimum service temperature: -40ºC (fixed and protected installations).

Mechanical performance

Minimum bending radius: x5 cable diameter.

Impact resistance: AG2 Medium severity.

Chemical performance

Chemical & Oil resistance: Acceptable.

Water performance

Water resistance: AD5 Jets.

Fire performance

Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.

Fire resistant:   (PH120) mínimum 120 minutes at 840ºC: Based on EN 50200 and  IEC 60331-2 for Ø cable < 20 mm.             

Based on EN 50362 and IEC 60331-1  for Ø cable > 20 mm.  180’ at 950ºC (cat C) category C,W & Z based on BS6387.

Fire resistant 180’ at 950ºC (cat C) category C,W & Z based on BS6387 (300/500V).

LSZH (Low Smoke Zero Halogen) based on  UNE-EN 60754-1 and IEC 60754-1.

Low smoke emission based on UNE-EN 61034 and IEC 61034: Light transmittance > 60%

Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

Other

Meter by meter marking.

Installation conditions

Open Air.

Buried.

In conduit.

Applications

Industrial use.

Emergency circuits

Public places.

TOXFREE PLUS 331 ZH RZ1-K AS+ cable design

Conductor

Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

Insulation

(2) Mica tape + (3) XLPE

The standard identification of insulated conductors is the following:

1 x   Natural

2x   Blue + Brown

3 G Blue + Brown + Green/yellow

4 G  Brown + Black + Grey + Green/yellow

5 G  Brown + Black + Grey + Green/yellow + Blue

Outer sheath

Low Smoke Zero Halogen (LSZH) polyolefin. Orange colour, non-toxic, fire retardant and fire resistant.


  • LOW VOLTAGE 0,6/1kV

  • Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

  • Maximum service temperature: 90ºC.

  • UNE-EN 60332-1 / UNE-EN 60332-3 / UNE-EN 50267-1 / UNE-EN 50267-2 / UNE-EN 61034 / UNE-EN 50200 / UNE-EN 50363

  • industrial use / Public places / Emergency circuits

Cable Specifications


CHEMICAL PERFORMANCE

  • Chemical & Oil resistance: Acceptable.

ELECTRICAL PERFORMANCE

  • LOW VOLTAGE 0,6/1kV

FIRE PERFORMANCE

  • Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.

  • Fire resistant 180’ at 950ºC (cat C) category C,W & Z based on BS6387 (300/500V).

  • Fire resistant: (PH120) mínimum 120 minutes at 840 ºC: Based on EN 50200 and IEC 60331-2 for Ø cable < 20 mm. Based on EN 50362 and IEC 60331-1 for Ø cable > 20 mm. 180’ at 950ºC (cat C) category C,W & Z based on BS6387.

  • Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

  • Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

  • Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%

  • LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1.

MECHANICAL PERFORMANCE

  • Impact resistance: AG2 Medium severity.

  • Minimum bending radius: x5 cable diameter.

THERMAL PERFORMANCE

  • Maximum service temperature: 90ºC.

  • Maximum short-circuit
    temperature: 250ºC (max. 5 s).

  • Minimum service temperature: -40ºC (fixed and protected installations)

WATER PERFORMANCE

  • Water resistance: AD5 Jets.

Other properties


APPLICATIONS

  • Emergency circuits

  • Industrial use.

  • Public places.

APPROVALS

  • CE

  • RoHS

BASED ON

  • IEC 60502-1 / UNE 211025

INSTALLATION CONDITIONS

  • Buried.

  • In conduit.

  • Open Air.

International norm

  • IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034 / IEC 60331-1 / IEC 60331-2

OTHERS

  • Meter by meter marking.

National norm / European:

  • UNE-EN 60332-1 / UNE-EN 60332-3 / UNE-EN 50267-1 / UNE-EN 50267-2 / UNE-EN 61034 / UNE-EN 50200 / UNE-EN 50363

Technology


  • 1. Conductor
    • Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
  • 2. Insulation
    • Mica tape + XLPE
    • The standard identification of insulated conductors is the following:
    • 1 x Natural
    • 2x Blue + Brown
    • 3 G Blue + Brown + Yellow/green
    • 4 G Brown + Black + Grey + Yellow/green
    • 5 G Brown + Black + Grey + Yellow/green + Blue
  • 3. Outer sheath
    • Low Smoke Zero Halogen (LSZH) polyolefin. Orange colour, non-toxic, fire retardant and fire resistant.

TECHNICAL & SALES SUPPORT

If you have any questions, please contact us. We’ll do our best to help.


[recaptcha]


Your message has been sent. Thank you

To download the cable datasheet, please complete the form below

[recaptcha]


Your message has been sent. Thank you