TOPDRIVE VFD (EMC) ROZ1-K (AS) 0,6/1kV cable has been specially designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI).
TOPDRIVE VFD (EMC) ROZ1-K (AS) 0,6/1kV cable has been specially designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI).
Electrical performance
LOW VOLTAGE 0,6/1 kV
Standard
IEC 60502-1 / IEC 60092-353
Approvals
DNV-GL / ABS /CE / RoHS
CPR Construction Product Regulation
Cca - s1a, d1, a1
Thermal performance
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations).
Fire performance
Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.
Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.
LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1.
Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%
Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
Reaction to fire CPR: Cca - s1a, d1, a1 , according to EN 50575.Mechanical performance
Minimum bending radius: x10 cable diameter.
Impact resistance: AG2 Medium severity.
Chemical performance
Chemical & Oil resistance: Good.
UV resistant based on UNE 211605 and EN 50618.Water performance
Water resistance: AD5 Jets.
Other
Meter by meter marking.
Ripcord.
Electric fields resistant.
Installation conditions
Open Air.
Buried.
In conduit.
Applications
Industrial use.
Variable Frequency Drive (VFD).
Electromagnetic protection.Conductor
Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
Grounding Conductor
The grounding conductor is divided into three conductors; the equivalent cross-section is approximately 50% of the section of the phase conductor.
Insulation
Cross-linked polyethylene (XLPE)
The standard identification of insulated conductors is the following:
4G grey + brown + black + Yellow/Green (up to 4 mm2)
3x + 3G grey + brown + black + Yellow/Green (3 x) (from 6 mm2 onwards)
Screen
Aluminium-polyester tape screen, helically placed over the insulated conductors. Over the tape there is a tinned copper braid screen. The tape and the braid act as a double screen to cut out all of the the electromagnetic interference.
The screen has a cover of 100% and its total section is approximately 10% of one of the conductors.
Outer sheath
Polyolefin LSHF outer sheath, black colour. The ripcord allows you to gently tear the outer-sheath allowing you to gently peel it away without damaging the screen.
CHEMICAL PERFORMANCE
Chemical & Oil resistance: Good.
UV Resistant: based on UNE 211605.
ELECTRICAL PERFORMANCE
LOW VOLTAGE 0.6/1 KV
FIRE PERFORMANCE
Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.
Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.
Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%
LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1.
MECHANICAL PERFORMANCE
Impact resistance: AG2 Medium severity.
Minimum bending radius: x10 cable diameter.
THERMAL PERFORMANCE
Maximum service temperature: 90ºC.
Maximum short-circuit
temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations)
WATER PERFORMANCE
Water resistance: AD5 Jets.
APPROVALS
ABS
CE
DNV-GL
RoHS
APPLICATIONS
Industrial use.
Variable Frequency Drive (VFD)
BASED ON
IEC 60502-1 / IEC 60092-353
INSTALLATION CONDITIONS
Buried.
In conduit.
Open Air.
CONSTRUCTION PRODUCT REGULATION
Cca s1a, d1, a1
OTHERS
Electric fields resistant.
Meter by meter marking.
Ripcord.
International norm
IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034
National norm / European:
UNE-EN 60332-1 / UNE-EN 60332-3-22 / UNE-EN 50267-1 / UNE-EN 61034
If you have any questions, please contact us. We’ll do our best to help.