TOXFREE MARINE PLUS XTCuZ1-K (AS+) cable performance
Electrical performance
LOW VOLTAGE 0,6/1kV
Electrical performance
LOW VOLTAGE 0,6/1kV
Standard
IEC 60092-353
Approvals
DNV-GL ABSBUREAU VERITAS
LLOYD'S REGISTER CERoHS
Thermal performance
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed installations).
Fire performance
Flame non-propagation according to IEC 60332-1.
Fire non-propagation according to IEC 60332-3-22. Fire resistant according to IEC 60331-21 (90 minutes at 750ºC). LSZH (Low Smoke Zero Halogen) according to IEC 60754-1. Low smoke emission according to IEC 61034: light transmittance > 60%. Low corrosive gases emission according to IEC 60754-2.Mechanical performance
Minimum bending radius: x6 cable diameter.
Impact resistance: AG3 High severity.
Chemical performance
Chemical & Oil resistance: Acceptable.
UV resistant according to EN 50618.Water performance
Water resistance: AD6 waves.
Other
Meter by meter marking.
Ripcord. Electric fields resistant.Installation conditions
Open Air.
In conduit.
On a bulkhead.
Applications
Marine use.
Public places.Conductor
Electrolytic copper, class 5 (flexible), based on EN 60228.
Insulation
Mica Tape + Cross linked polyethylene type XLPE 90ºC according to IEC 60092-360.
The standard identification is the following:
1x Natural
2 x Blue + Brown
3 x Brown + Black + Grey
4 x Brown + Black + Grey + Blue
5 or more conductors: black numbered
Other colors available on request.Armour
Coverage of 100% composed by aluminium-polyester tape and a tinned copper braid.
Outer sheath
LSHF thermoplastic polyolefin outer sheath SHF1 type. acording to IEC 60092-360. Orange color, non-toxic, fire retardant and fire resistant.
MECHANICAL PERFORMANCE
Impact resistance: AG3 High severity
ENVIRONMENTAL PERFORMANCE
Chemical & Oil resistance: Acceptable.
FIRE PERFORMANCE
Fire non-propagation based on EN 60332-3-22 and IEC 60332-3-22.
Fire resistant based on EN 60331-21 and IEC 60331-21.
Flame non-propagation based on EN 60332-1 and IEC 60332-1
ELECTRICAL PERFORMANCE
LOW VOLTAGE 0.6/1 KV
THERMAL PERFORMANCE
Maximum service temperature: 90ºC.
Maximum short-circuit
temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations)
WATER PERFORMANCE
Water resistance: AD6 waves
APPROVALS
ABS
BUREAU VERITAS
CE
DNV-GL
Lloyd’s Register
RoHS
BASED ON
STANDARD
IEC 60092-353
INSTALLATION CONDITIONS
In conduit.
On tray
Open Air.
Wall attached
APPLICATIONS
Marine use
Public places.
OTHERS
Meter by meter marking.
If you have any questions, please contact us. We’ll do our best to help.