TOXFREE MARINE XZ1-K (AS) cable performance
Electrical performance
LOW VOLTAGE 0,6/1kV
Electrical performance
LOW VOLTAGE 0,6/1kV
Standard
IEC 60502-1 / IEC 60092-353
Approvals
DNV-GL ABSBUREAU VERITAS
LLOYD'S REGISTER CERoHS
Thermal performance
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed installations).
Fire performance
Flame non-propagation based on EN 60332-1 and IEC 60332-1.
Fire non-propagation based on EN 60332-3-22 and IEC 60332-3-22. Fire resistant based on EN 60331-21 and IEC 60331-21. LSHF (Low Smoke Halogen Free) based on EN 60754-1 and IEC 60754-1. Low smoke emission based on EN 61034 and IEC 61034: light transmittance > 60%. Low corrosive gases emission based on EN 60754-2 and IEC 60754-2.Mechanical performance
Minimum bending radius: x5 cable diameter.
Impact resistance: AG2 medium severity.
Chemical performance
Chemical & Oil resistance: Good.
Water performance
Water resistance: AD6 waves.
Other
Meter by meter marking.
Installation conditions
Open Air.
Buried.
In conduit. On tray.Applications
Marine use.
Public places.Conductor
Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
Insulation
LSZH XLPE 90ºC.
The standard identification is the following:
1 x Natural
2 x Blue + Brown
3 x Brown + Black + Grey
4 x Brown + Black + Grey + Blue
5 or more conductors: white with black numbers
Outer sheath
Low smoke halogen free (LSHF) polyolefin outer sheath SHF1 type. Black colour, non-toxic, fire retardant.
ENVIRONMENTAL PERFORMANCE
Chemical & Oil resistance: Acceptable.
FIRE PERFORMANCE
Fire non-propagation based on EN 60332-3-22 and IEC 60332-3-22.
Flame non-propagation based on EN 60332-1 and IEC 60332-1
Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%
LSHF (Low Smoke Halogen Free) based on UNE-EN 60754-1 and IEC 60754-1.
MECHANICAL PERFORMANCE
Impact resistance: AG2 Medium severity.
Minimum bending radius: x5 cable diameter.
ELECTRICAL PERFORMANCE
LOW VOLTAGE 0,6/1kV
THERMAL PERFORMANCE
Maximum service temperature: 90ºC.
Maximum short-circuit
temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations)
WATER PERFORMANCE
Water resistance: AD6 waves
APPROVALS
ABS
BUREAU VERITAS
CE
DNV-GL
Lloyd’s Register
RoHS
STANDARD
IEC 60092-353
INSTALLATION CONDITIONS
In conduit.
On tray
Open Air.
Wall attached
APPLICATIONS
Marine use
Public places.
OTHERS
Meter by meter marking.