Electrical performance
LOW VOLTAGE 1,5/1,5 (1,8) kV DC according to EN 50618 | 1,8/3 (3,6) kV AC according to IEC 60502-1
Standard
IEC 60502-1
Approvals
RoHS / CE
Thermal performance
Maximum conductor temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations).
Minimum installation and handling temperature: 0°C (on cable surface).
Fire performance
Halogen free according to EN 60754-1 / IEC 60754-1.
Low corrosive gases emission according to EN 60754-2 / IEC 60754- 2.
Mechanical performance
Minimum bending radius: x5 cable diameter.
Impact resistance: AG4 (≤ 40 J) Extra high severity according to NF C 33-226. Abrasion according to NF C 33-226.Environmental performance
UV Resistant according to EN 50618.
Water resistance: AD8 Submersion.Installation conditions
Open air. Buried. In conduit.Other
Meter by meter marking.
Applications
Buried photovoltaic installations.
Conductor
Aluminium class 2 according to EN 60228 and IEC 60228.
Insulation
Cross-linked polyethylene type XLPE according to IEC 60502-1. Natural colour.
Outer sheath
Polyethylene halogen free and UV resistant, type ST7 according to IEC 60502-1 with extra thickness as protection for direct buried cables. Black colour.
MECHANICAL PERFORMANCE
Abrasion resistant.
Minimum bending radius: x5 cable diameter.
ENVIRONMENTAL PERFORMANCE
FIRE PERFORMANCE
Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.
ELECTRICAL PERFORMANCE
LOW VOLTAGE 1,5/1,5kV · ( 1,8) kV DC
THERMAL PERFORMANCE
Maximum service temperature: 90ºC.
Maximum short-circuit
temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations)
WATER PERFORMANCE
Water resistance: AD8 Submersion.
APPLICATIONS
Solar PV installations.
BASED ON
IEC 60502-1
INSTALLATION CONDITIONS
Buried.
In conduit.
Open Air.
APPROVALS
CE
RoHS
International norm
IEC 60502-1
OTHERS
Meter by meter marking.