Electrical performance
LOW VOLTAGE 1,5 (1,8) kV DC · 1,0/1,0 kV AC.
Standard
EN 50618 / IEC 62930 / UTE C 32-502
Approvals
TÜV / RETIE / CE / RoHS / AENOR / UKCA
CPR Construction Product Regulation
Thermal performance
Maximum conductor temperature: 90º (120ºC during 20000 h).
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC. (fixed and protected installations)
Fire performance
Flame non-propagation based on EN 60332-1-2 and IEC 60332-1-2.
LSHF (Low Smoke Halogen Free) based on EN 60754-1 and IEC 60754-1.
Low smoke emission based on EN 61034 and IEC 61034: Light transmittance > 60%
Low corrosive gases emission based on EN 60754-2 and IEC 60754-2.
Reaction to fire CPR: Cca -s1b, d2, a1, according to EN 50575.Mechanical performance
Minimum bending radius:
x4 cable diameter (≤ 8mm)
x5 cable diameter (8 < cable diameter ≤ 12)
x6 cable diameter (> 12mm)Impact resistance: AG2 Medium severity.
Chemical performance
Chemical & Oil resistance: Excellent.
Grease & mineral oils resistance: Excellent.
UV Resistant based on EN 50618 and IEC 62930.
Water performance
Water presence: AD8 submersion.
Estimated Lifetime
Estimated lifetime 30 years based on EN 50618.
Other
Meter by meter marking.
Optional: rodent-proof and termite-proof.
Installation conditions
Open Air.
Buried.
In conduit.Applications
Solar PV installations.
Packaging
Conductor
Class 5 (flexible) tinned copper, based on EN 60228 and IEC 60228.
Insulation
Low smoke halogen Free (LSHF) rubber according to table B1 in Annex B of EN 50618 and IEC 62930.
Outer sheath
Low smoke halogen Free (LSHF) rubber, red or black color.
CHEMICAL PERFORMANCE
Chemical & Oil resistance: Excellent.
Grease & mineral oils resistance: Excelente
UV Resistant based on EN 50618.
ELECTRICAL PERFORMANCE
LOW VOLTAGE 1,5/1,5kV · ( 1,8) kV DC
FIRE PERFORMANCE
Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.
Flame non-propagation based on EN 60332-1 and IEC 60332-1
MECHANICAL PERFORMANCE
Impact resistance: AG2 Medium severity.
Minimum bending radius: x5 cable diameter.
THERMAL PERFORMANCE
Maximum short-circuit
temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC.
WATER PERFORMANCE
Water resistance: AD8 Submersion.
APPROVALS
AENOR
CE
RoHS
TÜV
APPLICATIONS
Solar PV installations.
PACKAGING
Available in rolls (lengths of 50 and 100 m) and drums.
BASED ON
INSTALLATION CONDITIONS
Buried.
In conduit.
Open Air.
CONSTRUCTION PRODUCT REGULATION
Cca s1b, d2, a1
International norm
IEC 60332-1 / IEC 60754-1 / IEC 60754-2 / IEC 61034
OTHERS
Meter by meter marking.
If you have any questions, please contact us. We’ll do our best to help.