- Digital terrestrial television.
- Analogical satellite.
- Digital.
A complete range of LV cables developed under the most stringent international standards.
A full range of power, control, instrumentation and low voltage marine cables. All of them available in armoured and unarmoured versions and also according to the fire performances: flame and fire retardant, and fire resistant.
A complete range of LV cables developed under the most stringent international standards.
MARINE CABLESA full range of power, control, instrumentation and low voltage marine cables. All of them available in armoured and unarmoured versions and also according to the fire performances: flame and fire retardant, and fire resistant.
Electrical performance
Based on: EN 50117-1.
Standard & Approvals
CE RoHSConstruction Product Regulation
Eca
Thermal performance
Maximum service temperature: 70ºC.
Maximum short-circuit temperature: -15ºC (mobile service).
Other
Meter by meter marking.
Installation conditions
Open Air.
On tray.
In conduit.
Packaging
Available in 100m rolls.
Conductor
Electrolytic copper, class 1, based on EN 60228 and IEC 60228.
Insulation
Polyethylene HDPE according to UNE-EN 50290-2-23 .
Screen
Copper or aluminum screen and aluminum-polyester tape with overlapping copper braid, ensuring 100% screening coverage.
Outer sheath
PVC, white colour.
Eca
CE & RoHS
EN 50117-1
In conduit, on tray or open air
Meter by meter marking
Available in 100m rolls
THERMAL PERFORMANCE
Maximum service temperature: 70ºC.
Minimum service temperature: -15ºC
APPROVALS
CE
RoHS
BASED ON
CONSTRUCTION PRODUCT REGULATION
Eca
INSTALLATION CONDITIONS
In conduit.
On tray
Open Air.
OTHERS
Meter by meter marking.
Polyethylene HDPE according to UNE-EN 50290-2-23 .