FLEXTEL H05RNH2-F

Flexible cable for temporary installations 300/500V


The Flextel® H05RNH2-F is a flexible cable for mobile service. Suitable for temporary installations, both indoor and outdoor. The rectangular outer sheath with calibrated dimension makes it especially suitable for special lamp holders adapted to this type of cable.

FLEXTEL® H05RNH2-F cable performance

Electrical performance

Low voltage 300/500V.

Standard

EN 50525-2-82 / IEC 60245.

Approvals

RoHS

CE

Thermal performance

Maximum conductor temperature: 60ºC.

Maximum short-circuit temperature: 200ºC (max. 5 s).

Minimum service temperature: -40ºC (static with protection).

Fire performance

Flame non-propagation according to EN 60332-1 and IEC 60332-1.

Low halogen emission. Chlorine < 15%.

Mechanical performance

Minimum bending radius: 10 x cable diameter

Impact resistance: AG2 Medium severity.

Chemical performance

Chemical & Oil resistance: Good.

Other

Meter by meter marking.

Installation conditions

Open Air.

Buried. In conduit.

Applications

Temporary installations (indoor & outdoor).

FLEXTEL® H05RNH2-F cable design

Conductor

Electrolytic annealed copper, class 5 (flexible), according to EN 60228 and IEC 60228.

Insulation

Thermosetting rubber insulation, type EI4 according to EN 50363-1. The standard identification of insulated conductors is the following:

2 x Blue + Brown

Outer sheath

Thermosetting rubber outer sheath, white color, type EM2 according to EN 50363-2-1. Other colors available under request.


  • LOW VOLTAGE 300/500V

  • EN 50525 / IEC 60245

  • CE & RoHS

  • Chemical & Oil resistance: Good

  • Meter by meter marking

Cable Specifications


CHEMICAL PERFORMANCE

  • Chemical & Oil resistance: Good.

ELECTRICAL PERFORMANCE

  • LOW VOLTAGE 300/500 V

FIRE PERFORMANCE

  • Flame non-propagation based on EN 60332-1 and IEC 60332-1

  • Reduced halogen emission. Chlorine <15%.

MECHANICAL PERFORMANCE

  • Impact resistance: AG2 Medium severity.

  • Minimum bending radius: x10 cable diameter.

THERMAL PERFORMANCE

  • Maximum service temperature: 60ºC.

  • Maximum short-circuit temperature: 200°C (max. 5 s)
  • Minimum service temperature: -40ºC (fixed and protected installations)

Other properties


APPLICATIONS

  • Temporary site installations.

APPROVALS

  • CE

  • RoHS

INSTALLATION CONDITIONS

  • Buried.

  • In conduit.

  • Open Air.

BASED ON

  • EN 50525-2-82
  • IEC 60245

OTHERS

  • Meter by meter marking.

Technology


  • 1. Conductor
    • Electrolytic annealed copper, class 5 (flexible), based on EN 60228 and IEC 60228.
  • 2. Insulation
    • Thermosetting rubber insulation, type EI4 according to EN 50363-1. The standard identification of insulated conductors is the following:

      2 x Blue + Brown

  • 3. Outer sheath
    • Thermosetting rubber outer sheath, white color, type EM2 according to EN 50363-2-1. Other colors available under request.