TOXFREE® ZH ALARMS Z1OZ1-K (AS+)

Fire resistant cable for alarm systems


The TOXFREE® ZH ALARMS Z1OZ1-K (AS+) fire resistant cable is designed to comply with the regulations of Fire Detection Alarm systems. It is recommended to be used in public places. It should not be used for direct connection to the power supply network or other low impedance sources. · Fire detection. · Fire alarms.

TOXFREE® ZH ALARMS Z1OZ1-K (AS+) cable performance

Electrical performance

Low voltage: 300/500V.

Standard

UNE 211025-1.

Approvals

RoHS

CE

CPR

Cca -s1a, d1, a1 Thermal performance

Maximum service temperature: 70ºC.

Maximum short-circuit temperature: 160ºC (max. 5 s).

Minimum service temperature: -15ºC (fixed installation) and -5ºC (mobile use).

Fire performance

Flame non-propagation based on UNE-EN 50200 IEC 60332-1. Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399. Fire resistant based on IEC 60331-2 / EN 50200. Halogen free based on EN 60754 / IEC 60754. HCl content <0,5%. PH>4,3. Smoke density based on EN 61034 / IEC 61034. Light transmittance > 60%. Reaction to fire CPR: Cca -s1a, d1, a1, based on EN 50575.

Mechanical performance

Minimum bending radius:  x5 cable diameter.

Chemical performance

Chemical & Oil: acceptable.

Applications

· Fire detection.

· Fire alarms.

TOXFREE® ZH ALARMS Z1OZ1-K (AS) cable design

Conductor

Electrolytic copper, class 5 (flexible) based on UNE-EN 60228.

Insulation

Mica tape + special polyolefin insulation with low smoke emission and halogen-free. Conductor identification: red, black.

Screen

Overlapping aluminium - polyester tape screen with 100% coverage + tinned copper drainage wire.

Outer sheath

Outer sheath of fire-retardant polyolefin, red colour, with low smoke emission and halogen-free in case of fire.

  • Low voltage: 300/500V.

  • Fire alarms & Fire detection

  • CE & RoHS

  • une 211025

  • Chemical & Oil: acceptable.

  • Cca-s1a,d1,a1

  • Meter by meter marking.

  • Water resistance: AD3 Sprays.

Cable Specifications


CHEMICAL PERFORMANCE

  • Chemical & Oil resistance: Acceptable.

ELECTRICAL PERFORMANCE

  • LOW VOLTAGE 300/500 V

FIRE PERFORMANCE

  • Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.

  • Fire resistant based on IEC 60331-2 / EN 50200.

  • Flame non-propagation based on UNE-EN 50200 / IEC 60331-2.

  • Halogen free based on EN 60754.

  • Reaction to fire CPR: Cca-s1a, d1, a1, based on EN 50575.

  • Smoke density based on EN 61034 / IEC 61034. Light transmittance> 60%.

THERMAL PERFORMANCE

  • Maximum service temperature: 70ºC.

  • Maximum short-circuit
    temperature: 160ºC (max. 5 s).

  • Minimum service temperature: -15°C (fixed installation) and -5°C (mobile use).

MECHANICAL PERFORMANCE

  • Minimum bending radius: x5 cable diameter.

WATER PERFORMANCE

  • Water resistance: AD3 Sprays

Other properties


APPLICATIONS

  • Fire alarms

  • Fire detection

APPROVALS

  • CE

  • RoHS

BASED ON

  • UNE 211025

CONSTRUCTION PRODUCT REGULATION

  • Cca s1a, d1, a1

INSTALLATION CONDITIONS

  • In conduit.

  • On tray

  • Open Air.

OTHERS

  • Meter by meter marking.

Technology


  • 1. Conductor
    • Electrolytic copper, class 5 (flexible) based on UNE-EN 60228.
  • 2. Insulation
    • Mica tape + special polyolefin insulation with low smoke emission and halogen-free. Conductor identification: red, black.
  • 3. Screen
    • Overlapping aluminium – polyester tape screen with 100% coverage + tinned copper drainage wire.
  • 4. Outer sheath
    • Outer sheath of fire-retardant polyolefin, red colour, with low smoke emission and halogen-free in case of fire.

Other cables with similar properties