TOXFREE ZH ALARMS Z1OZ1-K (AS)

Cable for alarm systems


TOXFREE ZH ALARMS Z1OZ1-K (AS) cable is designed to comply with the regulations of Fire Detection and Alarm systems. It is recommended to be used in public places. It should not be used for direct connection to the power supply network or other low impedance sources.

TOXFREE ZH ALARMS Z1OZ1-K (AS) cable performance

Electrical performance

LOW VOLTAGE 300/500 V

Standard

UNE 211025

Approvals

RoHS / AENOR 

CPR Construction Product Regulation

Cca s1a, d1, a1

Thermal performance

Maximum service temperature: 70ºC.

Maximum short-circuit temperature: 160ºC (max. 5 s).

Minimum service temperature: -15ºC (static with protection).

Fire performance

Flame non-propagation according to EN 60332-1 and IEC 60332-1.

Fire non-propagation according to EN 60332-3 / IEC 60332-3 and EN 50399.

LSHF (Low Smoke Halogen Free) according to EN 60754-1 and IEC 60754-1.

Low smoke emission according to EN 61034 and IEC 61034: Light transmittance > 80%

Low corrosive gases emission according to EN 60754-2 and IEC 60754-2.

Reaction to fire CPR: Cca-s1a, d1, a1 according to EN 50575.

Mechanical performance

Minimum bending radius: 10x cable diameter.

Environmental performance

Chemical & Oil resistance: Acceptable.

Water resistance: AD3 Sprays

Installation conditions

Open air. In conduit. On tray.

Other

Meter by meter marking.

Applications

Fire detection.

Fire alarms.

TOXFREE ZH H05Z1Z1-F cable design

Conductor

Electrolytic annealed copper conductor class 5 (flexible) according to EN 60228 and IEC 60228.

Insulation

Special polyolefin insulation with low smoke emission and halogenfree.

Conductor identification: Red - Black.

Screen

Overlapping aluminium-polyester tape screen with 100% coverage + tinned copper drain wire.

Outer sheath

Fire-retardant polyolefin outer sheath with low smoke emission and halogen-free fumes in case of fire. Red colour.

DOWNLOAD DoP

  • Maximum service temperature: 70ºC.

  • Chemical & Oil resistance: Acceptable.

  • UNE 211025

Cable Specifications


ENVIRONMENTAL PERFORMANCE

  • Chemical & Oil resistance: Acceptable.

FIRE PERFORMANCE

  • Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.

  • Flame non-propagation based on EN 60332-1 and IEC 60332-1

  • Halogen free based on EN 60754-1
  • Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.

  • Low smoke emission according to EN 61034 and IEC 61034: Light transmittance > 80%.
  • Reaction to fire CPR: Cca-s1a, d1, a1, based on EN 50575.

ELECTRICAL PERFORMANCE

  • LOW VOLTAGE 300/500 V

THERMAL PERFORMANCE

  • Maximum service temperature: 70ºC.

  • Maximum short-circuit
    temperature: 160ºC (max. 5 s).

  • Minimum service temperature: -15ºC

MECHANICAL PERFORMANCE

  • Minimum bending radius: x10 cable diameter.

WATER PERFORMANCE

  • Water resistance: AD3 Sprays

Other properties


APPROVALS

  • AENOR

  • RoHS

BASED ON

  • UNE 211025

APPLICATIONS

  • Fire alarms

  • Fire detection

INSTALLATION CONDITIONS

  • In conduit.

  • On tray

  • Open Air.

OTHERS

  • Meter by meter marking.

Technology


  • 1. Conductor
    • Electrolytic annealed copper conductor class 5 (flexible) according to EN 60228 and IEC 60228.
  • 2. Insulation
    • Special polyolefin insulation with low smoke emission and halogenfree.
    • Conductor identification: Red – Black.
  • 3. Screen
    • Overlapping aluminium-polyester tape screen with 100% coverage + tinned copper drain wire.
  • 4. Outer sheath
    • Fire-retardant polyolefin outer sheath with low smoke emission and halogen-free fumes in case of fire. Red colour..