X-VOLT® TSLF

Cable for fixed installations.


X-VOLT® TSLF AL is a cable for fixed installations. Suitable for transport and distribution of electric power in medium voltage networks. Halogen free. This cable is suitable for indoor, outdoor and buried installations.

X-VOLT® TSLF AL cable performance

Electrical performance

MEDIUM VOLTAGE: 24/36 kV.

Standard

IEC 60502-2.

Construction Product Regulation

Eca

Thermal performance

Maximum service temperature: 90ºC.

Maximum short-circuit temperature: 250ºC (max. 5 s).

Minimum service temperature: -15ºC

Fire performance

Halogen free: according to EN 60754 / IEC 60754.

Reaction to fire CPR: Eca according to EN 50575.

Mechanical performance

Minimum bending radius: x15 cable diameter.

Abrasion-resistant.

Tear-resistant.

Installation conditions

Open Air.

Buried.

In conduit.

Applications

Distribution networks.

Other

Meter by meter marking.

X-VOLT® TSLF cable design

Conductor

Aluminium conductor, class 2 according to IEC 60228. Hygroscopic tapes applied in order to achieve longitudinal watertightness on the conductor.

Conductor screen

Cross-linked semiconductor screen applied over conductor in a triple - extrussion process.

Insulation

Cross-linked polyethylene insulation, type DIX8 according to HD 620; natural colour. Cross-linked in catenary line with nitrogen atmosphere.

Insulation screen 

Cross-linked semiconductor screen applied over insulation in a triple - extrussion process. Bonded to the insulation layer.

Longitudinal sealing

Hygroscopic tape completely covering the screen.

Metallic screen

Metallic screen with copper wires, applied over the semi - conducting tape. The metallic screen shall have a cross section of 25mm2 for 95mm2 core, 35mm2 for 150, 240 for 400mm2 core and 50mm2 for 630mm2 core.

Radial water-blocking barrier

Made up of an aluminium foil/polymer laminate (7) boned to the outer sheath.

External sheath

Polyethylene outer sheath, type DMP 17 according to HD 620; black colour (with conductive covering).


  • Medium voltage 24/36 kV.

  • Distribution networks

  • IEC 60502-2

  • Eca

  • Meter by meter marking.

Cable Specifications


MECHANICAL PERFORMANCE

  • Abrasion resistant.

  • Minimum bending radius: x 15 cable diameter.

  • Tear resistant.

ELECTRICAL PERFORMANCE

  • Medium voltage 24/36 kV.

THERMAL PERFORMANCE

  • Maximum service temperature: 90ºC.

  • Maximum short-circuit
    temperature: 250ºC (max. 5 s).

  • Minimum service temperature: -15ºC

Other properties


APPLICATIONS

  • Distribution networks.

BASED ON

  • IEC 60502-2.

INSTALLATION CONDITIONS

  • Buried.

  • In conduit.

  • Open Air.

CONSTRUCTION PRODUCT REGULATION

  • Eca

OTHERS

  • Meter by meter marking.

Technology


  • 1. Conductor
    • Aluminium conductor, class 2 according to IEC 60228. Hygroscopic tapes applied in order to achieve longitudinal watertightness on the conductor.
  • 2. Conductor screen
    • Cross-linked semiconductor screen applied over conductor in a triple – extrussion process.
  • 3. Insulation
    • Cross-linked polyethylene insulation, type DIX8 according to HD 620; natural colour. Cross-linked in catenary line with nitrogen atmosphere.
  • 4. Insulation screen
    • Cross-linked semiconductor screen applied over insulation in a triple – extrussion process. Bonded to the insulation layer.
  • 5. Longitudinal sealing
    • Hygroscopic tape completely covering the screen.
  • 6. Metallic screen
    • Metallic screen with copper wires, applied over the semi – conducting tape. The metallic screen shall have a cross section of 25mm2 for 95mm2 core, 35mm2 for 150, 240 for 400mm2 core and 50mm2 for 630mm2 core.
  • 7. Radial water-blocking barrier

    • Made up of an aluminium foil/polymer laminate (7) boned to the outer sheath.
  • 8. External sheath

    • Outer sheath of halogen-free polyolefin, red colour.

    • X-VOLT HEPRZ1 Cu/AL halogen-free polyolefin, red colour.
    •  X-VOLT HEPRZ1 Cu/AL (S) version is fire-retardant and halogen-free polyolefin, red colour with two grey bands.
    • X-VOLT HEPRZ1 Cu/AL (AS) version is fire-retardant and halogen-free polyolefin, red colour with two green bands.

     

TECHNICAL & SALES SUPPORT

If you have any questions, please contact us. We’ll do our best to help.



    Your message has been sent. Thank you

    To download the cable datasheet, please complete the form below


      Your message has been sent. Thank you